I'm not a RF design expert, but shouldn't RF RX paths (N$49 at your schematic for v3) be merged using some impedance matching ? Integrated resistor divider (losses >= 6dB) or Wilkinson divider (losses >= 3dB). They cost pennies (~$0.3).
There is two inductor L1 and L2 and two Cap C22 with C20 for impedance matching. So it is basically doing what resistive splitter is doing.