[Feature Request] Backflow/Export Setting - Solis #313

Closed J14111 closed 1 year ago

J14111 commented 1 year ago

Thanks for all the amazing work, I have another request when you have the time, would it be possible to have this as a slider:

image

I have had a look but I cant figure out which register it is, it would help my stop my hot water diverter kicking in when I dont want it to as I can disable any export.

Thanks.

wills106 commented 1 year ago

Thanks, just seen it. I think they are a very good company and I like their innovative tariffs they offer.

Out of curiosity were you able to fully complete the signup online or do you still have to phone up to move over?

J14111 commented 1 year ago

I was getting ready to phone them but its all online again now which is great, I need to get a smart meter even though I dont want one so I can get paid for export, I think im going to be generating a lot more than I can store/use in the summer so makes sense

wills106 commented 1 year ago

all online again now which is great

That's good to know.

going to be generating a lot more than I can store/use in the summer so makes sense

I think they have a really good Export Tariff and it's worth having for Late Spring - Early Autumn.

J14111 commented 1 year ago

Yeah I will probably go on one of their smart tariffs over the winter to fill the batteries up, not much point now

Baker0052 commented 1 year ago

On my Solis-S5-EH1P46K-L when i set Backflow Power to 300W it sets it to 3.000.000W

Baker0052 commented 1 year ago

Ok changing the "Scale =0.01" to "Scale = 100" seems to work. Had to restart HA.