Closed itsnotlevel1 closed 1 year ago
Can you screenshot your your probe settings.
Thanks, I see the problem now when trying the same settings on my machine. It was hardly noticeable when using "smaller" values so I never caught this. It is getting late here, so I'll take a look at it tomorrow morning.
Yes sir .... Please take your time, it's the weekend. 😁. Btw.... Those are imperial measurements just incase I didn't specify. Thanks!
I think that I figured it out. It is available in the latest nightly build: https://github.com/winder/Universal-G-Code-Sender#downloads
Very nice....it works great! You are a coding god! Thank you for your time.
Excellent, thanks for the feedback. Is it ok to close the issue?
Yes, I believe so.
Paul
-------- Original Message -------- On Aug 21, 2023, 12:10 PM, Joacim Breiler wrote:
Excellent, thanks for the feedback. Is it ok to close the issue?
— Reply to this email directly, view it on GitHub, or unsubscribe. You are receiving this because you authored the thread.Message ID: @.***>
Version
2.0.19
Hardware / Firmware
FluidNC
What happened
I have been trying to make the probe function work and it actually only worked ONCE...lol. Now whenever using the xyz probe function: Z works great....X works great.....but when the spindle moves over the touch the Y side, it over shoots the probe by at least 1 inch.....??? Video below.
https://drive.google.com/file/d/1dL07ceMukKIUcAebgRDHZZhMMcU-098Y/view?usp=sharing
How to reproduce
Just run probe again.
Operating System
Linux Mint 20.2
Anything else
everytime