Re-burst first CV value C4 (0V) #14

Open paulpiko opened 4 years ago

paulpiko commented 4 years ago

The CV value on the first trigger out of a burst is always C4 (0V), even in the random modes. IOW, not random. Easiest to see if you set repet to 1 or 2, and hook Hot Tuna/Volt Meter to the CV out