Closed DARKSPARKLER closed 2 years ago
I can't repro this one at all. I'd have to see it.
I can't replicate this either.
Ok weird. I reverted back to an earlier version of the firmware from July that didn't have this issue because I have a show on Thursday and I needed to start practicing for it. I probably won't pull out the MARF to put the new firmware back on there to shoot a video till Friday, so hang tight.
I re-uploaded this firmware today and I'm still getting this double pulse issue. Here is a video showing the issue:
Thanks, Kyle.
This one was real. It was tricky to see because the second ghost pulse was only a fraction of a ms and didn't light the led.
Fixed by 9118f63.
I just came across an issue where pulses are firing on the following stage even if it doesn't have a pulse programmed. For example, if you have pulse output 1 programmed on stages 1 and 5, pulses will fire on stages 1&2, then 5&6. Both AFG's are functioning like this, and both pulse outputs have the same behavior when programmed.