Open GoogleCodeExporter opened 9 years ago
When the bus is free, at times it does not transmit anyone can produce
erroneous readings due to noise in the pair
To avoid this, it puts a pull-up resistance in the A and a pull-down, in the B,
thus, a potential is fixed to the case that all release the bus.
Interestingly, only affected the transmission, that appeared a "1" ghost, which
falsified the total data received ..
No problems in the library
Original comment by ja...@apsingenieros.es
on 5 Jan 2013 at 12:12
After chatting with Jaime he actually stumbled on the fault himself by
monitoring the buffer value and realizing it always contains a byte after a
second packet was sent until the retry count expires. As the libraries have
been tested extensively on commercial equipment the fault would most likely be
a hardware or connection fault between his master and slave (two mega2560's).
Checking the connections to his RS485 converter I suggested to use 680ohm pull
up and pull down resistors on the master side to ensure the bus is in a known
state before requesting. This solved his problem.
Original comment by bester.j...@gmail.com
on 7 Jan 2013 at 6:58
[deleted comment]
Google translator -> Hello, I would like to know how to write with this library
in single registrar (function 6 - Modbus). My machine does not have access to
function 16. thank you.
Original comment by alisson....@gmail.com
on 19 May 2014 at 12:45
Original issue reported on code.google.com by
ja...@apsingenieros.es
on 28 Dec 2012 at 4:21Attachments: