majordom21 commented 6 years ago

Hello,

I'm a newbie with this software. I'm learning how to use it. I've got only comware switches.

Comware 3 : old 3 com (42100, 5500) Comware 5 : HP 3600 Comware 7 : HP 5120 5130

Everything is OK with comware 5 but I've got issue with comware 3&7.

"raised Timeout::Error with msg "execution expired""

I found in your doc your command "info-center source default channel 1 log state off debug state off" but it does not resolv the problem.

I don't know well enough to understand why ? If someone can help me I'd appreciate.

-- Dom

Sorry for my english

majordom21 commented 6 years ago

Ok I find a way for comware 3 in using vrp model (Huawei). But I can't find the solution for comware7 (HP 5120 & 5130)

majordom21 commented 6 years ago

OK, I find the solution. It was a timeout problem on a stack. you can close

martinohansen commented 6 years ago

@majordom21 can you elaborate on what you did to solve this on issue on Comware 7? Thanks. We're currently experiencing the same issue.

majordom21 commented 6 years ago

I wrote timeout: 600 in the config file. The switch to analyse is a 5 devices stack. It need more time

martinohansen commented 6 years ago

Solved the issue in #1583, thanks.