Open GoogleCodeExporter opened 9 years ago
When I enable PRINT_ANALOGS, I get a data stream that appears to be in the
following order: Accel P Y R, Angle P R Y, Magneto P R Y. This is based on
which numbers change and how, as I change the board's orientation. It does
*not* appear to match what the output lines claim to be outputting, which is
Angle (AN), Accel (ACC), Magneto. The third number in the second triad
("ACC[2]") does not change appreciably as yaw changes (it fluctuates a bit but
appears to be within the normal noise for that data triad).
I have made no changes to the AHRS code except to enable PRINT_ANALOGS.
Original comment by jmcole...@gmail.com
on 2 Nov 2010 at 8:39
Please ignore my comment about values being in the wrong order, I went back and
read the datasheets for the chips and they're correct. Still having heading not
track properly.
Original comment by jmcole...@gmail.com
on 3 Nov 2010 at 4:09
maybe that's the same issue than "Issue 21: Yaw drifts to SE even when
stationary"? might have found a solution for that one...
Greetings,
Gerold
Original comment by gerold.h...@gmail.com
on 20 Mar 2011 at 10:59
Original issue reported on code.google.com by
jmcole...@gmail.com
on 2 Nov 2010 at 7:50