Closed zapccu closed 8 months ago
Multiple channels with role: UNIVERSAL_LIGHT_RECEIVER One channel (5) with role: UNIVERSAL_LIGHT_WEEK_PROFILE
Datapoints:
3.ACTIVITY_STATE = 0 {i} [RE] 3.COLOR_TEMPERATURE = 0 {i} [RWE] 3.COLOR_TEMPERATURE_STATUS = 0 {i} [RE] 3.COMBINED_PARAMETER = {s} [W] 3.DIM2WARM_STATE = false {b} [RE] 3.DURATION_UNIT = {i} [W] 3.DURATION_VALUE = {i} [W] 3.EFFECT = {i} [W] 3.HUE = 0 {i} [RWE] 3.HUE_STATUS = 0 {i} [RE] 3.HUMAN_CENTRIC_LIGHT_STATE = false {b} [RE] 3.LEVEL = 0.000000 {f} [RWE] 3.LEVEL_STATUS = 0 {i} [RE] 3.PROCESS = 0 {i} [RE] 3.RAMP_TIME_TO_OFF_UNIT = {i} [W] 3.RAMP_TIME_TO_OFF_VALUE = {i} [W] 3.RAMP_TIME_UNIT = {i} [W] 3.RAMP_TIME_VALUE = {i} [W] 3.SATURATION = 0.000000 {f} [RWE] 3.SATURATION_STATUS = 0 {i} [RE] 3.SECTION = 0 {i} [RE] 3.SECTION_STATUS = 0 {i} [RE] 5.COMBINED_PARAMETER = {s} [W] 5.WEEK_PROGRAM_CHANNEL_LOCKS = 0 {i} [RE] 5.WEEK_PROGRAM_TARGET_CHANNEL_LOCK = {i} [W] 5.WEEK_PROGRAM_TARGET_CHANNEL_LOCKS = {i} [W]
Setting COMBINED_PARAMETER: "L=33,H=9,SAT=77,OT=0,RT=0,RTTDV=0,RTTDU=0"
Shortcuts:
L: Level = Helligkeitswert [0-100] Integer als % Wert; 0 = Aus; 100 = Ein; 101 = Ignorieren OT: On Time = Einschaltdauer [0 - 108000] Basiseinheit: Sekunden; mit 0 = Dauer an = 31 hrs RT: Ramp (up) Time = Rampenzeit [ 0 - ?? ] Basiseinheit: Sekunden H: Hue = Farbwert "H" [0° - 360°] in Grad SAT: Saturation = Sättigung = "S" [0-100] Integer als % Wert RTTOV: Ramp Time to OFF Value = Ausschalt-Rampenzeit Dauer [ 0 - ?? ] Ausschalt-Rampenzeit: Wert RTTOU: Ramp Time to OFF Unit = Ausschalt-Rampenzeit-Einheit {0, 1, 3} Ausschalt-Rampenzeit: Wert 0 = sec; 1 = min; 3 = ms
Added command "set color" using COMBINED_PARAMETER "L=n,H=n,SAT=n".
Usage: set xy color Level Hue Saturation
Multiple channels with role: UNIVERSAL_LIGHT_RECEIVER One channel (5) with role: UNIVERSAL_LIGHT_WEEK_PROFILE
Datapoints:
Setting COMBINED_PARAMETER: "L=33,H=9,SAT=77,OT=0,RT=0,RTTDV=0,RTTDU=0"
Shortcuts:
L: Level = Helligkeitswert [0-100] Integer als % Wert; 0 = Aus; 100 = Ein; 101 = Ignorieren OT: On Time = Einschaltdauer [0 - 108000] Basiseinheit: Sekunden; mit 0 = Dauer an = 31 hrs RT: Ramp (up) Time = Rampenzeit [ 0 - ?? ] Basiseinheit: Sekunden H: Hue = Farbwert "H" [0° - 360°] in Grad SAT: Saturation = Sättigung = "S" [0-100] Integer als % Wert RTTOV: Ramp Time to OFF Value = Ausschalt-Rampenzeit Dauer [ 0 - ?? ] Ausschalt-Rampenzeit: Wert RTTOU: Ramp Time to OFF Unit = Ausschalt-Rampenzeit-Einheit {0, 1, 3} Ausschalt-Rampenzeit: Wert 0 = sec; 1 = min; 3 = ms