zephyriot / zep-jira14

0 stars 0 forks source link

AON Counter : ISR triggered twice on ARC #1411

Closed nashif closed 7 years ago

nashif commented 7 years ago

Reported by Qiu Peiyang:

Configuration

arc mount atlas unified Bug detailed description =================== AON Counter ISR is triggered twice on ARC in one circulation. Testcase to Reproduce ================== 1. Apply the patch https://gerrit.zephyrproject.org/r/#/c/9659/ 2. cd tests/drivers/test_aon_upstream 3. make pristine && make BOARD=quark_se_c1000_ss_devboard flash Expected Result ============= Case passes and actual_alarm_cnt = 3 Actual Result ========== Case fails and actual_alarm_cnt = 6 (Imported from Jira ZEP-1545)
nashif commented 7 years ago

by Qiu Peiyang:

Any update ?

nashif commented 7 years ago

by Mark Linkmeyer:

Correcting the priority field

nashif commented 7 years ago

by Kuo-Lang Tseng:

According to Baohong's current patch, the fix is in QMSI driver code so when next QMSI release that has this fix is integrated into Zephyr, this bug can be verified and closed at that time.

nashif commented 7 years ago

by Kuo-Lang Tseng:

The fix is in next QMSI release and once we integrate it, the bug can be verified and closed.

nashif commented 7 years ago

by Kuo-Lang Tseng:

Qiu Peiyang QMSI 1.4 RC2 has been merged. Please verify if this issues is fixed.

nashif commented 7 years ago

by Qiu Peiyang:

Patch has been merged and this issue has gone. Can be verified by https://gerrit.zephyrproject.org/r/#/c/11025/

Close this bug.