Fibaro covers doesn't report state after update to HA-Addon 1.13.1 #5825

Closed memphi2 closed 1 year ago

memphi2 commented 1 year ago

Is your problem within Home Assistant (Core or Z-Wave JS Integration)?

YES, BUT a Home Assistant developer has told me to come here

Is your problem within Z-Wave JS UI (formerly ZwaveJS2MQTT)?

YES, BUT a Z-Wave JS UI developer has told me to come here

Checklist

Describe the bug

After updating to 1.13.1 my fibaro covers doesn't report the state after open/close command via HA I can see in the zwave log that the covers are receiving the new target value, but i'm not receiving the current value. When i operate the covers manually the state is reported and I'm receiveing the current value. It seems this relies on https://github.com/zwave-js/node-zwave-js/pull/5807

What causes the bug?

Change in the state of a fibaro cover (open/close) via HA

no state change in HA

What did you expect to happen?

correct state in HA

Device information

Manufacturer: fibaro Model name: FGR223 Node ID in your network: 2-7

How are you using node-zwave-js?

Which branches or versions?

version: 1.13.1 node-zwave-js branch: zwave-js-ui branch:

Did you change anything?

yes (please describe)

If yes, what did you change?

Updated from 1.13.0 to 1.13.1

Did this work before?

Yes (please describe)

If yes, where did it work?

worked in 1.13.0

Attach Driver Logfile

command send via HA:

2023-05-21 15:35:34.566 INFO Z-WAVE: [Node 031] Value updated: 50-0-value-66049 0 => 0 2023-05-21 15:36:01.920 INFO Z-WAVE: [Node 003] Value updated: 38-1-targetValue 86 => 99 2023-05-21 15:36:04.590 INFO Z-WAVE: [Node 003] Metadata updated: 50-1-value-66049 2023-05-21 15:36:04.594 INFO Z-WAVE: [Node 003] Value updated: 50-1-value-66049 0.6 => 102.9 2023-05-21 15:36:09.394 INFO Z-WAVE: [Node 003] Metadata updated: 50-1-value-66049 2023-05-21 15:36:09.400 INFO Z-WAVE: [Node 003] Value updated: 50-1-value-66049 102.9 => 0.6

operated manually: 2023-05-21 15:39:58.424 INFO Z-WAVE: [Node 003] Value updated: 50-1-value-66049 0.6 => 61.2 2023-05-21 15:40:03.225 INFO Z-WAVE: [Node 003] Value updated: 38-1-targetValue 78 => 99 2023-05-21 15:40:03.231 INFO Z-WAVE: [Node 003] Value updated: 38-1-duration unknown => unknown 2023-05-21 15:40:03.234 INFO Z-WAVE: [Node 003] Value updated: 38-1-currentValue 86 => 99 2023-05-21 15:40:04.409 INFO Z-WAVE: [Node 003] Metadata updated: 50-1-value-66049 2023-05-21 15:40:04.413 INFO Z-WAVE: [Node 003] Value updated: 50-1-value-66049 61.2 => 0.6

command send via HA / version 1.13.0: 2023-05-21 16:01:54.621 INFO Z-WAVE: [Node 003] Value updated: 38-1-targetValue 90 => 99 2023-05-21 16:01:57.117 INFO Z-WAVE: [Node 003] Metadata updated: 50-1-value-66049 2023-05-21 16:01:57.124 INFO Z-WAVE: [Node 003] Value updated: 50-1-value-66049 1.9 => 80.8 2023-05-21T14:01:59.070Z CNTRLR « [Node 003] Received update for a Supervision session 2023-05-21 16:01:59.072 INFO Z-WAVE: [Node 003] Value updated: 38-1-currentValue 90 => 99 2023-05-21 16:02:00.744 INFO Z-WAVE: [Node 003] Metadata updated: 50-1-value-66049 2023-05-21 16:02:00.748 INFO Z-WAVE: [Node 003] Value updated: 50-1-value-66049 80.8 => 0.6

zwave-js-bot commented 1 year ago

👋 Hey @memphi2!

Thanks for opening an issue! It doesn't look like you provided a logfile though. While not strictly necessary for every issue, having a driver log is required to diagnose most issues.

Please consider uploading a logfile that captures your problem.

AlCalzone commented 1 year ago

What the bot said :)

lucas-clemente commented 1 year ago

I’m seeing the same issue, started a few days ago. I’ll try to get you a log file tonight.

I did try to manually refresh the state in the ZWave UI, but that only temporarily fixed the issue.

AlCalzone commented 1 year ago

Please don't comment without a logfile, that's just noise.

lucas-clemente commented 1 year ago

Log attached. The event I triggered was to half-closed at 15:18:44. The shutter moved to half-closed but HA shows it as fully closed, just like all the other open ones.

zwave-js-ui-store.zip

AlCalzone commented 1 year ago

relevant log snippet:

2023-05-23T15:18:44.251Z DRIVER » [Node 004] [REQ] [SendData]
                                  │ transmit options: 0x25
                                  │ callback id:      11
                                  └─[Security2CCMessageEncapsulation]
                                    │ sequence number: 36
                                    │ extensions:
                                    │ · type: SPAN
                                    │   sender EI: 0x8d77687108e3641dd78a7c927bb3c8a3
                                    └─[MultiChannelCCCommandEncapsulation]
                                      │ source:      0
                                      │ destination: 1
                                      └─[SupervisionCCGet]
                                        │ session id:      56
                                        │ request updates: true
                                        └─[MultilevelSwitchCCSet]
                                            target value: 56
2023-05-23T15:18:44.255Z SERIAL « [ACK]                                                                   (0x06)
2023-05-23T15:18:44.262Z SERIAL « 0x0104011301e8                                                       (6 bytes)
2023-05-23T15:18:44.263Z SERIAL » [ACK]                                                                   (0x06)
2023-05-23T15:18:44.264Z DRIVER « [RES] [SendData]
                                    was sent: true
2023-05-23T15:18:44.286Z SERIAL « 0x011800130b00000200d27f7f7f7f00000300000000030100002e              (26 bytes)
2023-05-23T15:18:44.287Z SERIAL » [ACK]                                                                   (0x06)
2023-05-23T15:18:44.288Z DRIVER « [REQ] [SendData]
                                    callback id:            11
                                    transmit status:        OK, took 20 ms
                                    routing attempts:       1
                                    protocol & route speed: Z-Wave, 100 kbit/s
                                    ACK RSSI:               -46 dBm
                                    ACK channel no.:        0
                                    TX channel no.:         0
2023-05-23T15:18:44.357Z SERIAL « 0x011d00040004159f03d400e3f9d2cae3fc3e0311da0443b3babbe6d1d00046    (31 bytes)
2023-05-23T15:18:44.362Z SERIAL » [ACK]                                                                   (0x06)
2023-05-23T15:18:44.364Z DRIVER « [Node 004] [REQ] [ApplicationCommand]
                                  └─[Security2CCMessageEncapsulation]
                                    │ sequence number: 212
                                    └─[MultiChannelCCCommandEncapsulation]
                                      │ source:      1
                                      │ destination: 0
                                      └─[SupervisionCCReport]
                                          session id:          56
                                          more updates follow: true
                                          status:              Working
                                          duration:            25s
2023-05-23T15:18:47.098Z SERIAL « 0x0122000400041a9f03d500895d9f7037d4910233f5e718a302bf73b8691dcc047 (36 bytes)
                                  4d00031
2023-05-23T15:18:47.104Z SERIAL » [ACK]                                                                   (0x06)
2023-05-23T15:18:47.110Z CNTRLR   [Node 004] [Meter] value[66049]: metadata updated                 [Endpoint 1]
2023-05-23T15:18:47.113Z CNTRLR   [Node 004] [~] [Meter] value[66049]: 0 => 108.2                   [Endpoint 1]
2023-05-23T15:18:47.116Z DRIVER « [Node 004] [REQ] [ApplicationCommand]
                                  └─[Security2CCMessageEncapsulation]
                                    │ sequence number: 213
                                    └─[MultiChannelCCCommandEncapsulation]
                                      │ source:      1
                                      │ destination: 0
                                      └─[MeterCCReport]
                                          type:       Electric
                                          scale:      W
                                          rate type:  Consumed
                                          value:      108.2
                                          time delta: 0 seconds
2023-05-23T15:18:59.085Z SERIAL « 0x011d00040004159f03d600d911f386a4b70c3682098d57ab97faa8d2d20016    (31 bytes)
2023-05-23T15:18:59.094Z SERIAL » [ACK]                                                                   (0x06)
2023-05-23T15:18:59.097Z DRIVER « [Node 004] [REQ] [ApplicationCommand]
                                  └─[Security2CCMessageEncapsulation]
                                    │ sequence number: 214
                                    └─[MultiChannelCCCommandEncapsulation]
                                      │ source:      1
                                      │ destination: 0
                                      └─[SupervisionCCReport]
                                          session id:          56
                                          more updates follow: false
                                          status:              Success
                                          duration:            0s

no value update as result of the success.

thecobra666 commented 1 year ago

I have the same issue, since updating my docker container to the latest version, I can see the request showing up in the logs after a clicked a button or tried to switch on/off a device, but it does not report back to HA.

Does not matter which device. I have it with fibaro, qubino, sensative..

• Application Logs are disabled. Please enable it on "Settings > General" in order to see ZwaveJS logs

Filter logs
Type to filter logs, case sensitive
14:01:19.692 SERIAL » [ACK] (0x06)
14:01:19.693 DRIVER « [RES] [SendData]
was sent: true
14:01:19.712 SERIAL « 0x011800131900000200c77f7f7f7f000003000000000301000029 (26 bytes)
14:01:19.713 SERIAL » [ACK] (0x06)
14:01:19.715 DRIVER « [REQ] [SendData]
callback id: 25
transmit status: OK, took 20 ms
routing attempts: 1
protocol & route speed: Z-Wave, 100 kbit/s
ACK RSSI: -57 dBm
ACK channel no.: 0
TX channel no.: 0
14:01:19.724 CNTRLR [Node 013] [~] [Binary Switch] currentValue: false => false [Endpoint 0]
14:01:20.738 SERIAL » 0x010900130d029840251a0d (11 bytes)
14:01:20.740 DRIVER » [Node 013] [REQ] [SendData]
│ transmit options: 0x25
│ callback id: 26
└─[SecurityCCNonceGet]
14:01:20.743 SERIAL « [ACK] (0x06)
14:01:20.747 SERIAL « 0x0104011301e8 (6 bytes)
14:01:20.749 SERIAL » [ACK] (0x06)
14:01:20.750 DRIVER « [RES] [SendData]
was sent: true
14:01:20.767 SERIAL « 0x011800131a00000200c77f7f7f7f00000300000000030100002a (26 bytes)
14:01:20.769 SERIAL » [ACK] (0x06)
14:01:20.770 DRIVER « [REQ] [SendData]
callback id: 26
transmit status: OK, took 20 ms
routing attempts: 1
protocol & route speed: Z-Wave, 100 kbit/s
ACK RSSI: -57 dBm
ACK channel no.: 0
TX channel no.: 0
14:01:20.782 SERIAL « 0x01120004000d0a98801786998d612c01cec70036 (20 bytes)
14:01:20.784 SERIAL » [ACK] (0x06)
14:01:20.786 DRIVER « [Node 013] [REQ] [ApplicationCommand]
└─[SecurityCCNonceReport]
nonce: 0x1786998d612c01ce
14:01:20.794 SERIAL » 0x011d00130d1698815e57145de7f37e4f834c1e17d83c7a62769c989f251b7f (31 bytes)
14:01:20.796 DRIVER » [Node 013] [REQ] [SendData]
│ transmit options: 0x25
│ callback id: 27
└─[SecurityCCCommandEncapsulation]
│ nonce id: 23
└─[BinarySwitchCCGet]
14:01:20.799 SERIAL « [ACK] (0x06)
14:01:20.805 SERIAL « 0x0104011301e8 (6 bytes)
14:01:20.807 SERIAL » [ACK] (0x06)
14:01:20.808 DRIVER « [RES] [SendData]
was sent: true
14:01:20.827 SERIAL « 0x011800131b00000200c77f7f7f7f00000300000000030100002b (26 bytes)
14:01:20.830 SERIAL » [ACK] (0x06)
14:01:20.832 DRIVER « [REQ] [SendData]
callback id: 27
transmit status: OK, took 20 ms
routing attempts: 1
protocol & route speed: Z-Wave, 100 kbit/s
ACK RSSI: -57 dBm
ACK channel no.: 0
TX channel no.: 0
14:01:20.844 SERIAL « 0x010a0004000d029840c700e1 (12 bytes)
14:01:20.846 SERIAL » [ACK] (0x06)
14:01:20.849 DRIVER « [Node 013] [REQ] [ApplicationCommand]
└─[SecurityCCNonceGet]
14:01:20.867 SERIAL » 0x011100130d0a98809fb6dde65ee88eb1051c60 (19 bytes)
14:01:20.868 DRIVER » [Node 013] [REQ] [SendData]
│ transmit options: 0x05
│ callback id: 28
└─[SecurityCCNonceReport]
nonce: 0x9fb6dde65ee88eb1
14:01:20.871 SERIAL « [ACK] (0x06)
14:01:20.876 SERIAL « 0x0104011301e8 (6 bytes)
14:01:20.878 SERIAL » [ACK] (0x06)
14:01:20.879 DRIVER « [RES] [SendData]
was sent: true
14:01:20.896 SERIAL « 0x011800131c00000200c97f7f7f7f000003000000000301000022 (26 bytes)
14:01:20.897 SERIAL » [ACK] (0x06)
14:01:20.899 DRIVER « [REQ] [SendData]
callback id: 28
transmit status: OK, took 20 ms
routing attempts: 1
protocol & route speed: Z-Wave, 100 kbit/s
ACK RSSI: -55 dBm
ACK channel no.: 0
TX channel no.: 0
14:01:20.916 SERIAL « 0x011f0004000d179881aeebed83b0074a255d57717f9f27f8184573cb7415c7001 (33 bytes)
3
14:01:20.918 SERIAL » [ACK] (0x06)
14:01:20.921 CNTRLR [Node 013] [~] [Binary Switch] currentValue: false => false [Endpoint 0]
14:01:20.924 DRIVER « [Node 013] [REQ] [ApplicationCommand]
└─[SecurityCCCommandEncapsulation]
│ sequenced: false
└─[BinarySwitchCCReport]
current value: false
14:01:21.286 SERIAL » 0x010a00131c03250100251de5 (12 bytes)
14:01:21.287 DRIVER » [Node 028] [REQ] [SendData]
│ transmit options: 0x25
│ callback id: 29
└─[BinarySwitchCCSet]
target value: false
14:01:21.290 SERIAL « [ACK] (0x06)
14:01:21.295 SERIAL « 0x0104011301e8 (6 bytes)
14:01:21.297 SERIAL » [ACK] (0x06)
14:01:21.299 DRIVER « [RES] [SendData]
was sent: true
14:01:21.320 SERIAL « 0x011800131d00000200d57f7f7f7f01010300000000020100003e (26 bytes)
14:01:21.321 SERIAL » [ACK] (0x06)
14:01:21.323 DRIVER « [REQ] [SendData]
callback id: 29
transmit status: OK, took 20 ms
routing attempts: 1
protocol & route speed: Z-Wave, 40 kbit/s
ACK RSSI: -43 dBm
ACK channel no.: 1
TX channel no.: 1
14:01:21.332 CNTRLR [Node 028] [~] [Binary Switch] currentValue: false => false [Endpoint 0]
14:01:22.341 SERIAL » 0x010900131c022502251ee7 (11 bytes)
14:01:22.343 DRIVER » [Node 028] [REQ] [SendData]
│ transmit options: 0x25
│ callback id: 30
└─[BinarySwitchCCGet]
14:01:22.347 SERIAL « [ACK] (0x06)
14:01:22.350 SERIAL « 0x0104011301e8 (6 bytes)
14:01:22.352 SERIAL » [ACK] (0x06)
14:01:22.354 DRIVER « [RES] [SendData]
was sent: true
14:01:22.375 SERIAL « 0x011800131e00000300d57f7f7f7f01010300000000020100003c (26 bytes)
14:01:22.376 SERIAL » [ACK] (0x06)
14:01:22.377 DRIVER « [REQ] [SendData]
callback id: 30
transmit status: OK, took 30 ms
routing attempts: 1
protocol & route speed: Z-Wave, 40 kbit/s
ACK RSSI: -43 dBm
ACK channel no.: 1
TX channel no.: 1
14:01:22.411 SERIAL « 0x010b0004001c03250300d5001c (13 bytes)
14:01:22.412 SERIAL » [ACK] (0x06)
14:01:22.414 CNTRLR [Node 028] [~] [Binary Switch] currentValue: false => false [Endpoint 0]
14:01:22.416 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[BinarySwitchCCReport]
current value: false
14:01:30.195 SERIAL « 0x01120004003d0a32022134000000470000d2006e (20 bytes)
14:01:30.203 SERIAL » [ACK] (0x06)
14:01:30.210 CNTRLR [Node 061] [Meter] value[66049]: metadata updated [Endpoint 0]
14:01:30.215 CNTRLR [Node 061] [~] [Meter] value[66049]: 6.8 => 7.1 [Endpoint 0]
14:01:30.220 DRIVER « [Node 061] [REQ] [ApplicationCommand]
└─[MeterCCReport]
type: Electric
scale: W
rate type: Consumed
value: 7.1
time delta: 0 seconds
14:01:31.194 SERIAL « 0x01120004003d0a32022134000000000000d20029 (20 bytes)
14:01:31.198 SERIAL » [ACK] (0x06)
14:01:31.203 CNTRLR [Node 061] [Meter] value[66049]: metadata updated [Endpoint 0]
14:01:31.207 CNTRLR [Node 061] [~] [Meter] value[66049]: 7.1 => 0 [Endpoint 0]
14:01:31.212 DRIVER « [Node 061] [REQ] [ApplicationCommand]
└─[MeterCCReport]
type: Electric
scale: W
rate type: Consumed
value: 0
time delta: 0 seconds
14:01:32.192 SERIAL « 0x010b0004003d03260300d20039 (13 bytes)
14:01:32.197 SERIAL » [ACK] (0x06)
14:01:32.202 CNTRLR [Node 061] [~] [Multilevel Switch] currentValue: 99 => 0 [Endpoint 0]
14:01:32.206 DRIVER « [Node 061] [REQ] [ApplicationCommand]
└─[MultilevelSwitchCCReport]
current value: 0
14:01:34.254 SERIAL « 0x010f0004001c07600d0100250300d50070 (17 bytes)
14:01:34.260 SERIAL » [ACK] (0x06)
14:01:34.264 CNTRLR [Node 028] [~] [Binary Switch] currentValue: false => false [Endpoint 1]
14:01:34.268 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 1
│ destination: 0
└─[BinarySwitchCCReport]
current value: false
14:01:34.935 SERIAL » 0x0103003bc7 (5 bytes)
14:01:34.938 DRIVER » [REQ] [GetBackgroundRSSI]
14:01:34.942 SERIAL « [ACK] (0x06)
14:01:34.945 SERIAL « 0x0105013bb3b3c0 (7 bytes)
14:01:34.948 SERIAL » [ACK] (0x06)
14:01:34.950 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -77 dBm
channel 1: -77 dBm
14:01:35.270 SERIAL « 0x01160004001c0e600d010032022134000000000000d50063 (24 bytes)
14:01:35.276 SERIAL » [ACK] (0x06)
14:01:35.281 CNTRLR [Node 028] [Meter] value[66049]: metadata updated [Endpoint 1]
14:01:35.287 CNTRLR [Node 028] [~] [Meter] value[66049]: 0 => 0 [Endpoint 1]
14:01:35.294 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 1
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: W
rate type: Consumed
value: 0
time delta: 0 seconds
14:01:36.253 SERIAL « 0x010f0004001c07600d0200250300cf0069 (17 bytes)
14:01:36.258 SERIAL » [ACK] (0x06)
14:01:36.261 CNTRLR [Node 028] [~] [Binary Switch] currentValue: false => false [Endpoint 2]
14:01:36.265 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 2
│ destination: 0
└─[BinarySwitchCCReport]
current value: false
14:01:37.278 SERIAL « 0x01160004001c0e600d020032022134000000000000d50060 (24 bytes)
14:01:37.281 SERIAL » [ACK] (0x06)
14:01:37.284 CNTRLR [Node 028] [Meter] value[66049]: metadata updated [Endpoint 2]
14:01:37.288 CNTRLR [Node 028] [~] [Meter] value[66049]: 0 => 0 [Endpoint 2]
14:01:37.293 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 2
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: W
rate type: Consumed
value: 0
time delta: 0 seconds
14:01:39.288 SERIAL « 0x01160004001c0e600d020032022124000000000000d50070 (24 bytes)
14:01:39.290 SERIAL » [ACK] (0x06)
14:01:39.293 CNTRLR [Node 028] [Meter] value[65537]: metadata updated [Endpoint 2]
14:01:39.295 CNTRLR [Node 028] [~] [Meter] value[65537]: 0 => 0 [Endpoint 2]
14:01:39.299 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 2
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: kWh
rate type: Consumed
value: 0
time delta: 0 seconds
14:02:04.943 SERIAL » 0x0103003bc7 (5 bytes)
14:02:04.947 DRIVER » [REQ] [GetBackgroundRSSI]
14:02:04.955 SERIAL « [ACK] (0x06)
14:02:04.961 SERIAL « 0x0105013bb3aedd (7 bytes)
14:02:04.965 SERIAL » [ACK] (0x06)
14:02:04.968 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -77 dBm
channel 1: -82 dBm
14:02:34.939 SERIAL » 0x0103003bc7 (5 bytes)
14:02:34.943 DRIVER » [REQ] [GetBackgroundRSSI]
14:02:34.949 SERIAL « [ACK] (0x06)
14:02:34.953 SERIAL « 0x0105013bb5abde (7 bytes)
14:02:34.956 SERIAL » [ACK] (0x06)
14:02:34.959 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -75 dBm
channel 1: -85 dBm
14:03:04.941 SERIAL » 0x0103003bc7 (5 bytes)
14:03:04.945 DRIVER » [REQ] [GetBackgroundRSSI]
14:03:04.950 SERIAL « [ACK] (0x06)
14:03:04.954 SERIAL « 0x0105013bb0abdb (7 bytes)
14:03:04.957 SERIAL » [ACK] (0x06)
14:03:04.960 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -80 dBm
channel 1: -85 dBm
14:03:34.939 SERIAL » 0x0103003bc7 (5 bytes)
14:03:34.943 DRIVER » [REQ] [GetBackgroundRSSI]
14:03:34.948 SERIAL « [ACK] (0x06)
14:03:34.952 SERIAL « 0x0105013bb3b0c3 (7 bytes)
14:03:34.954 SERIAL » [ACK] (0x06)
14:03:34.956 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -77 dBm
channel 1: -80 dBm
14:04:04.944 SERIAL » 0x0103003bc7 (5 bytes)
14:04:04.948 DRIVER » [REQ] [GetBackgroundRSSI]
14:04:04.954 SERIAL « [ACK] (0x06)
14:04:04.959 SERIAL « 0x0105013bb3b0c3 (7 bytes)
14:04:04.962 SERIAL » [ACK] (0x06)
14:04:04.965 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -77 dBm
channel 1: -80 dBm
14:04:28.967 SERIAL « 0x01160004001c0e600d010032022134000000000000d50063 (24 bytes)
14:04:28.978 SERIAL » [ACK] (0x06)
14:04:28.984 CNTRLR [Node 028] [Meter] value[66049]: metadata updated [Endpoint 1]
14:04:28.989 CNTRLR [Node 028] [~] [Meter] value[66049]: 0 => 0 [Endpoint 1]
14:04:28.994 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 1
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: W
rate type: Consumed
value: 0
time delta: 0 seconds
14:04:30.975 SERIAL « 0x01160004001c0e600d020032022134000000000000ca007f (24 bytes)
14:04:30.980 SERIAL » [ACK] (0x06)
14:04:30.988 CNTRLR [Node 028] [Meter] value[66049]: metadata updated [Endpoint 2]
14:04:30.993 CNTRLR [Node 028] [~] [Meter] value[66049]: 0 => 0 [Endpoint 2]
14:04:30.997 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 2
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: W
rate type: Consumed
value: 0
time delta: 0 seconds
14:04:34.940 SERIAL » 0x0103003bc7 (5 bytes)
14:04:34.943 DRIVER » [REQ] [GetBackgroundRSSI]
14:04:34.953 SERIAL « [ACK] (0x06)
14:04:34.961 SERIAL « 0x0105013bb1b0c1 (7 bytes)
14:04:34.964 SERIAL » [ACK] (0x06)
14:04:34.968 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -79 dBm
channel 1: -80 dBm
14:04:34.991 SERIAL « 0x01160004001c0e600d010032022124000000000000d50073 (24 bytes)
14:04:35.000 SERIAL » [ACK] (0x06)
14:04:35.002 CNTRLR [Node 028] [Meter] value[65537]: metadata updated [Endpoint 1]
14:04:35.005 CNTRLR [Node 028] [~] [Meter] value[65537]: 0 => 0 [Endpoint 1]
14:04:35.009 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 1
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: kWh
rate type: Consumed
value: 0
time delta: 0 seconds
14:04:36.999 SERIAL « 0x01160004001c0e600d020032022124000000000000d70072 (24 bytes)
14:04:37.002 SERIAL » [ACK] (0x06)
14:04:37.004 CNTRLR [Node 028] [Meter] value[65537]: metadata updated [Endpoint 2]
14:04:37.006 CNTRLR [Node 028] [~] [Meter] value[65537]: 0 => 0 [Endpoint 2]
14:04:37.008 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 2
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: kWh
rate type: Consumed
value: 0
time delta: 0 seconds
14:05:04.938 SERIAL » 0x0103003bc7 (5 bytes)
14:05:04.942 DRIVER » [REQ] [GetBackgroundRSSI]
14:05:04.951 SERIAL « [ACK] (0x06)
14:05:04.955 SERIAL « 0x0105013bb3aedd (7 bytes)
14:05:04.958 SERIAL » [ACK] (0x06)
14:05:04.961 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -77 dBm
channel 1: -82 dBm
14:05:34.942 SERIAL » 0x0103003bc7 (5 bytes)
14:05:34.946 DRIVER » [REQ] [GetBackgroundRSSI]
14:05:34.951 SERIAL « [ACK] (0x06)
14:05:34.955 SERIAL « 0x0105013bb3aedd (7 bytes)
14:05:34.957 SERIAL » [ACK] (0x06)
14:05:34.960 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -77 dBm
channel 1: -82 dBm
14:06:02.292 SERIAL » 0x010a00131c03250100251fe7 (12 bytes)
14:06:02.296 DRIVER » [Node 028] [REQ] [SendData]
│ transmit options: 0x25
│ callback id: 31
└─[BinarySwitchCCSet]
target value: false
14:06:02.303 SERIAL « [ACK] (0x06)
14:06:02.313 SERIAL « 0x0104011301e8 (6 bytes)
14:06:02.317 SERIAL » [ACK] (0x06)
14:06:02.321 DRIVER « [RES] [SendData]
was sent: true
14:06:02.328 SERIAL « 0x011800131f00000200c97f7f7f7f010103000000000201000020 (26 bytes)
14:06:02.330 SERIAL » [ACK] (0x06)
14:06:02.331 DRIVER « [REQ] [SendData]
callback id: 31
transmit status: OK, took 20 ms
routing attempts: 1
protocol & route speed: Z-Wave, 40 kbit/s
ACK RSSI: -55 dBm
ACK channel no.: 1
TX channel no.: 1
14:06:02.343 CNTRLR [Node 028] [~] [Binary Switch] currentValue: false => false [Endpoint 0]
14:06:03.355 SERIAL » 0x010900131c0225022520d9 (11 bytes)
14:06:03.357 DRIVER » [Node 028] [REQ] [SendData]
│ transmit options: 0x25
│ callback id: 32
└─[BinarySwitchCCGet]
14:06:03.360 SERIAL « [ACK] (0x06)
14:06:03.364 SERIAL « 0x0104011301e8 (6 bytes)
14:06:03.366 SERIAL » [ACK] (0x06)
14:06:03.368 DRIVER « [RES] [SendData]
was sent: true
14:06:03.389 SERIAL « 0x011800132000000200d57f7f7f7f010103000000000201000003 (26 bytes)
14:06:03.390 SERIAL » [ACK] (0x06)
14:06:03.392 DRIVER « [REQ] [SendData]
callback id: 32
transmit status: OK, took 20 ms
routing attempts: 1
protocol & route speed: Z-Wave, 40 kbit/s
ACK RSSI: -43 dBm
ACK channel no.: 1
TX channel no.: 1
14:06:03.425 SERIAL « 0x010b0004001c03250300d5001c (13 bytes)
14:06:03.427 SERIAL » [ACK] (0x06)
14:06:03.429 CNTRLR [Node 028] [~] [Binary Switch] currentValue: false => false [Endpoint 0]
14:06:03.433 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[BinarySwitchCCReport]
current value: false
14:06:08.455 SERIAL » 0x0103003bc7 (5 bytes)
14:06:08.457 DRIVER » [REQ] [GetBackgroundRSSI]
14:06:08.462 SERIAL « [ACK] (0x06)
14:06:08.470 SERIAL « 0x0105013bb0b1c1 (7 bytes)
14:06:08.473 SERIAL » [ACK] (0x06)
14:06:08.476 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -80 dBm
channel 1: -79 dBm
14:06:15.363 SERIAL « 0x010f0004001c07600d0100250300d50070 (17 bytes)
14:06:15.370 SERIAL » [ACK] (0x06)
14:06:15.374 CNTRLR [Node 028] [~] [Binary Switch] currentValue: false => false [Endpoint 1]
14:06:15.379 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 1
│ destination: 0
└─[BinarySwitchCCReport]
current value: false
14:06:16.387 SERIAL « 0x01160004001c0e600d010032022134000000000000d50063 (24 bytes)
14:06:16.392 SERIAL » [ACK] (0x06)
14:06:16.397 CNTRLR [Node 028] [Meter] value[66049]: metadata updated [Endpoint 1]
14:06:16.401 CNTRLR [Node 028] [~] [Meter] value[66049]: 0 => 0 [Endpoint 1]
14:06:16.405 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 1
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: W
rate type: Consumed
value: 0
time delta: 0 seconds
14:06:17.370 SERIAL « 0x010f0004001c07600d0200250300d50073 (17 bytes)
14:06:17.373 SERIAL » [ACK] (0x06)
14:06:17.375 CNTRLR [Node 028] [~] [Binary Switch] currentValue: false => false [Endpoint 2]
14:06:17.377 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 2
│ destination: 0
└─[BinarySwitchCCReport]
current value: false
14:06:18.396 SERIAL « 0x01160004001c0e600d020032022134000000000000d50060 (24 bytes)
14:06:18.399 SERIAL » [ACK] (0x06)
14:06:18.401 CNTRLR [Node 028] [Meter] value[66049]: metadata updated [Endpoint 2]
14:06:18.404 CNTRLR [Node 028] [~] [Meter] value[66049]: 0 => 0 [Endpoint 2]
14:06:18.406 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 2
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: W
rate type: Consumed
value: 0
time delta: 0 seconds
14:06:20.406 SERIAL « 0x01160004001c0e600d020032022124000000000000d50070 (24 bytes)
14:06:20.408 SERIAL » [ACK] (0x06)
14:06:20.410 CNTRLR [Node 028] [Meter] value[65537]: metadata updated [Endpoint 2]
14:06:20.412 CNTRLR [Node 028] [~] [Meter] value[65537]: 0 => 0 [Endpoint 2]
14:06:20.414 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 2
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: kWh
rate type: Consumed
value: 0
time delta: 0 seconds
14:06:38.459 SERIAL » 0x0103003bc7 (5 bytes)
14:06:38.463 DRIVER » [REQ] [GetBackgroundRSSI]
14:06:38.468 SERIAL « [ACK] (0x06)
14:06:38.476 SERIAL « 0x0105013bb5b1c4 (7 bytes)
14:06:38.480 SERIAL » [ACK] (0x06)
14:06:38.484 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -75 dBm
channel 1: -79 dBm
14:07:08.459 SERIAL » 0x0103003bc7 (5 bytes)
14:07:08.464 DRIVER » [REQ] [GetBackgroundRSSI]
14:07:08.470 SERIAL « [ACK] (0x06)
14:07:08.476 SERIAL « 0x0105013bb5b1c4 (7 bytes)
14:07:08.479 SERIAL » [ACK] (0x06)
14:07:08.483 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -75 dBm
channel 1: -79 dBm
14:07:38.457 SERIAL » 0x0103003bc7 (5 bytes)
14:07:38.461 DRIVER » [REQ] [GetBackgroundRSSI]
14:07:38.469 SERIAL « [ACK] (0x06)
14:07:38.473 SERIAL « 0x0105013bb0b0c0 (7 bytes)
14:07:38.475 SERIAL » [ACK] (0x06)
14:07:38.478 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -80 dBm
channel 1: -80 dBm
14:08:08.457 SERIAL » 0x0103003bc7 (5 bytes)
14:08:08.460 DRIVER » [REQ] [GetBackgroundRSSI]
14:08:08.465 SERIAL « [ACK] (0x06)
14:08:08.469 SERIAL « 0x0105013baeaec0 (7 bytes)
14:08:08.472 SERIAL » [ACK] (0x06)
14:08:08.475 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -82 dBm
channel 1: -82 dBm
14:08:38.461 SERIAL » 0x0103003bc7 (5 bytes)
14:08:38.465 DRIVER » [REQ] [GetBackgroundRSSI]
14:08:38.471 SERIAL « [ACK] (0x06)
14:08:38.475 SERIAL « 0x0105013bb3b1c2 (7 bytes)
14:08:38.478 SERIAL » [ACK] (0x06)
14:08:38.481 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -77 dBm
channel 1: -79 dBm
14:08:44.981 SERIAL « 0x01160004001c0e600d010032022134000000000000d70061 (24 bytes)
14:08:44.996 SERIAL » [ACK] (0x06)
14:08:45.002 CNTRLR [Node 028] [Meter] value[66049]: metadata updated [Endpoint 1]
14:08:45.007 CNTRLR [Node 028] [~] [Meter] value[66049]: 0 => 0 [Endpoint 1]
14:08:45.011 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 1
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: W
rate type: Consumed
value: 0
time delta: 0 seconds
14:08:46.990 SERIAL « 0x01160004001c0e600d020032022134000000000000d50060 (24 bytes)
14:08:46.995 SERIAL » [ACK] (0x06)
14:08:47.000 CNTRLR [Node 028] [Meter] value[66049]: metadata updated [Endpoint 2]
14:08:47.004 CNTRLR [Node 028] [~] [Meter] value[66049]: 0 => 0 [Endpoint 2]
14:08:47.008 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 2
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: W
rate type: Consumed
value: 0
time delta: 0 seconds
14:08:51.008 SERIAL « 0x01160004001c0e600d010032022124000000000000d50073 (24 bytes)
14:08:51.013 SERIAL » [ACK] (0x06)
14:08:51.017 CNTRLR [Node 028] [Meter] value[65537]: metadata updated [Endpoint 1]
14:08:51.021 CNTRLR [Node 028] [~] [Meter] value[65537]: 0 => 0 [Endpoint 1]
14:08:51.025 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 1
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: kWh
rate type: Consumed
value: 0
time delta: 0 seconds
14:08:53.017 SERIAL « 0x01160004001c0e600d020032022124000000000000ca006f (24 bytes)
14:08:53.019 SERIAL » [ACK] (0x06)
14:08:53.021 CNTRLR [Node 028] [Meter] value[65537]: metadata updated [Endpoint 2]
14:08:53.024 CNTRLR [Node 028] [~] [Meter] value[65537]: 0 => 0 [Endpoint 2]
14:08:53.026 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 2
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: kWh
rate type: Consumed
value: 0
time delta: 0 seconds
14:09:08.458 SERIAL » 0x0103003bc7 (5 bytes)
14:09:08.461 DRIVER » [REQ] [GetBackgroundRSSI]
14:09:08.466 SERIAL « [ACK] (0x06)
14:09:08.470 SERIAL « 0x0105013bb3aedd (7 bytes)
14:09:08.473 SERIAL » [ACK] (0x06)
14:09:08.476 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -77 dBm
channel 1: -82 dBm
14:09:38.461 SERIAL » 0x0103003bc7 (5 bytes)
14:09:38.465 DRIVER » [REQ] [GetBackgroundRSSI]
14:09:38.470 SERIAL « [ACK] (0x06)
14:09:38.475 SERIAL « 0x0105013baeaec0 (7 bytes)
14:09:38.478 SERIAL » [ACK] (0x06)
14:09:38.482 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -82 dBm
channel 1: -82 dBm
14:10:08.454 SERIAL » 0x0103003bc7 (5 bytes)
14:10:08.458 DRIVER » [REQ] [GetBackgroundRSSI]
14:10:08.466 SERIAL « [ACK] (0x06)
14:10:08.470 SERIAL « 0x0105013bb5aedb (7 bytes)
14:10:08.473 SERIAL » [ACK] (0x06)
14:10:08.476 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -75 dBm
channel 1: -82 dBm
14:10:10.646 SERIAL » 0x010a00131c032501002521d9 (12 bytes)
14:10:10.648 DRIVER » [Node 028] [REQ] [SendData]
│ transmit options: 0x25
│ callback id: 33
└─[BinarySwitchCCSet]
target value: false
14:10:10.651 SERIAL « [ACK] (0x06)
14:10:10.657 SERIAL « 0x0104011301e8 (6 bytes)
14:10:10.659 SERIAL » [ACK] (0x06)
14:10:10.661 DRIVER « [RES] [SendData]
was sent: true
14:10:10.680 SERIAL « 0x011800132100000200d57f7f7f7f010103000000000201000002 (26 bytes)
14:10:10.682 SERIAL » [ACK] (0x06)
14:10:10.683 DRIVER « [REQ] [SendData]
callback id: 33
transmit status: OK, took 20 ms
routing attempts: 1
protocol & route speed: Z-Wave, 40 kbit/s
ACK RSSI: -43 dBm
ACK channel no.: 1
TX channel no.: 1
14:10:10.695 CNTRLR [Node 028] [~] [Binary Switch] currentValue: false => false [Endpoint 0]
14:10:11.708 SERIAL » 0x010900131c0225022522db (11 bytes)
14:10:11.710 DRIVER » [Node 028] [REQ] [SendData]
│ transmit options: 0x25
│ callback id: 34
└─[BinarySwitchCCGet]
14:10:11.715 SERIAL « [ACK] (0x06)
14:10:11.719 SERIAL « 0x0104011301e8 (6 bytes)
14:10:11.721 SERIAL » [ACK] (0x06)
14:10:11.724 DRIVER « [RES] [SendData]
was sent: true
14:10:11.741 SERIAL « 0x011800132200000300d57f7f7f7f010103000000000201000000 (26 bytes)
14:10:11.743 SERIAL » [ACK] (0x06)
14:10:11.744 DRIVER « [REQ] [SendData]
callback id: 34
transmit status: OK, took 30 ms
routing attempts: 1
protocol & route speed: Z-Wave, 40 kbit/s
ACK RSSI: -43 dBm
ACK channel no.: 1
TX channel no.: 1
14:10:11.778 SERIAL « 0x010b0004001c03250300d5001c (13 bytes)
14:10:11.780 SERIAL » [ACK] (0x06)
14:10:11.781 CNTRLR [Node 028] [~] [Binary Switch] currentValue: false => false [Endpoint 0]
14:10:11.784 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[BinarySwitchCCReport]
current value: false
14:10:23.351 SERIAL « 0x010f0004001c07600d0100250300d50070 (17 bytes)
14:10:23.356 SERIAL » [ACK] (0x06)
14:10:23.360 CNTRLR [Node 028] [~] [Binary Switch] currentValue: false => false [Endpoint 1]
14:10:23.364 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 1
│ destination: 0
└─[BinarySwitchCCReport]
current value: false
14:10:24.376 SERIAL « 0x01160004001c0e600d010032022134000000000000d50063 (24 bytes)
14:10:24.381 SERIAL » [ACK] (0x06)
14:10:24.385 CNTRLR [Node 028] [Meter] value[66049]: metadata updated [Endpoint 1]
14:10:24.389 CNTRLR [Node 028] [~] [Meter] value[66049]: 0 => 0 [Endpoint 1]
14:10:24.392 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 1
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: W
rate type: Consumed
value: 0
time delta: 0 seconds
14:10:25.360 SERIAL « 0x010f0004001c07600d0200250300d50073 (17 bytes)
14:10:25.365 SERIAL » [ACK] (0x06)
14:10:25.368 CNTRLR [Node 028] [~] [Binary Switch] currentValue: false => false [Endpoint 2]
14:10:25.371 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 2
│ destination: 0
└─[BinarySwitchCCReport]
current value: false
14:10:26.386 SERIAL « 0x01160004001c0e600d020032022134000000000000d50060 (24 bytes)
14:10:26.394 SERIAL » [ACK] (0x06)
14:10:26.399 CNTRLR [Node 028] [Meter] value[66049]: metadata updated [Endpoint 2]
14:10:26.404 CNTRLR [Node 028] [~] [Meter] value[66049]: 0 => 0 [Endpoint 2]
14:10:26.409 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 2
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: W
rate type: Consumed
value: 0
time delta: 0 seconds
14:10:28.395 SERIAL « 0x01160004001c0e600d020032022124000000000000cf006a (24 bytes)
14:10:28.400 SERIAL » [ACK] (0x06)
14:10:28.410 CNTRLR [Node 028] [Meter] value[65537]: metadata updated [Endpoint 2]
14:10:28.414 CNTRLR [Node 028] [~] [Meter] value[65537]: 0 => 0 [Endpoint 2]
14:10:28.419 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 2
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: kWh
rate type: Consumed
value: 0
time delta: 0 seconds
14:10:38.455 SERIAL » 0x0103003bc7 (5 bytes)
14:10:38.458 DRIVER » [REQ] [GetBackgroundRSSI]
14:10:38.470 SERIAL « [ACK] (0x06)
14:10:38.475 SERIAL « 0x0105013bb1a8d9 (7 bytes)
14:10:38.478 SERIAL » [ACK] (0x06)
14:10:38.482 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -79 dBm
channel 1: -88 dBm
14:11:08.457 SERIAL » 0x0103003bc7 (5 bytes)
14:11:08.461 DRIVER » [REQ] [GetBackgroundRSSI]
14:11:08.469 SERIAL « [ACK] (0x06)
14:11:08.474 SERIAL « 0x0105013bb0addd (7 bytes)
14:11:08.477 SERIAL » [ACK] (0x06)
14:11:08.482 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -80 dBm
channel 1: -83 dBm
14:11:38.457 SERIAL » 0x0103003bc7 (5 bytes)
14:11:38.460 DRIVER » [REQ] [GetBackgroundRSSI]
14:11:38.466 SERIAL « [ACK] (0x06)
14:11:38.470 SERIAL « 0x0105013bb3aad9 (7 bytes)
14:11:38.474 SERIAL » [ACK] (0x06)
14:11:38.477 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -77 dBm
channel 1: -86 dBm
14:12:08.458 SERIAL » 0x0103003bc7 (5 bytes)
14:12:08.461 DRIVER » [REQ] [GetBackgroundRSSI]
14:12:08.466 SERIAL « [ACK] (0x06)
14:12:08.471 SERIAL « 0x0105013bb0aede (7 bytes)
14:12:08.474 SERIAL » [ACK] (0x06)
14:12:08.478 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -80 dBm
channel 1: -82 dBm
14:12:38.455 SERIAL » 0x0103003bc7 (5 bytes)
14:12:38.459 DRIVER » [REQ] [GetBackgroundRSSI]
14:12:38.465 SERIAL « [ACK] (0x06)
14:12:38.474 SERIAL « 0x0105013bb1a7d6 (7 bytes)
14:12:38.477 SERIAL » [ACK] (0x06)
14:12:38.482 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -79 dBm
channel 1: -89 dBm
14:13:01.004 SERIAL « 0x01160004001c0e600d010032022134000000000000ca007c (24 bytes)
14:13:01.016 SERIAL » [ACK] (0x06)
14:13:01.021 CNTRLR [Node 028] [Meter] value[66049]: metadata updated [Endpoint 1]
14:13:01.026 CNTRLR [Node 028] [~] [Meter] value[66049]: 0 => 0 [Endpoint 1]
14:13:01.035 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 1
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: W
rate type: Consumed
value: 0
time delta: 0 seconds
14:13:03.013 SERIAL « 0x01160004001c0e600d020032022134000000000000d50060 (24 bytes)
14:13:03.018 SERIAL » [ACK] (0x06)
14:13:03.026 CNTRLR [Node 028] [Meter] value[66049]: metadata updated [Endpoint 2]
14:13:03.035 CNTRLR [Node 028] [~] [Meter] value[66049]: 0 => 0 [Endpoint 2]
14:13:03.040 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 2
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: W
rate type: Consumed
value: 0
time delta: 0 seconds
14:13:07.031 SERIAL « 0x01160004001c0e600d010032022124000000000000d50073 (24 bytes)
14:13:07.034 SERIAL » [ACK] (0x06)
14:13:07.036 CNTRLR [Node 028] [Meter] value[65537]: metadata updated [Endpoint 1]
14:13:07.038 CNTRLR [Node 028] [~] [Meter] value[65537]: 0 => 0 [Endpoint 1]
14:13:07.040 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 1
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: kWh
rate type: Consumed
value: 0
time delta: 0 seconds
14:13:08.455 SERIAL » 0x0103003bc7 (5 bytes)
14:13:08.457 DRIVER » [REQ] [GetBackgroundRSSI]
14:13:08.465 SERIAL « [ACK] (0x06)
14:13:08.470 SERIAL « 0x0105013bb5aedb (7 bytes)
14:13:08.473 SERIAL » [ACK] (0x06)
14:13:08.477 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -75 dBm
channel 1: -82 dBm
14:13:09.040 SERIAL « 0x01160004001c0e600d020032022124000000000000c9006c (24 bytes)
14:13:09.042 SERIAL » [ACK] (0x06)
14:13:09.046 CNTRLR [Node 028] [Meter] value[65537]: metadata updated [Endpoint 2]
14:13:09.049 CNTRLR [Node 028] [~] [Meter] value[65537]: 0 => 0 [Endpoint 2]
14:13:09.051 DRIVER « [Node 028] [REQ] [ApplicationCommand]
└─[MultiChannelCCCommandEncapsulation]
│ source: 2
│ destination: 0
└─[MeterCCReport]
type: Electric
scale: kWh
rate type: Consumed
value: 0
time delta: 0 seconds
14:13:38.458 SERIAL » 0x0103003bc7 (5 bytes)
14:13:38.462 DRIVER » [REQ] [GetBackgroundRSSI]
14:13:38.470 SERIAL « [ACK] (0x06)
14:13:38.474 SERIAL « 0x0105013bb5b0c5 (7 bytes)
14:13:38.478 SERIAL » [ACK] (0x06)
14:13:38.482 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -75 dBm
channel 1: -80 dBm
14:13:58.805 SERIAL » 0x010a001305032501ff25233d (12 bytes)
14:13:58.812 DRIVER » [Node 005] [REQ] [SendData]
│ transmit options: 0x25
│ callback id: 35
└─[BinarySwitchCCSet]
target value: true
14:13:58.818 SERIAL « [ACK] (0x06)
14:13:58.823 SERIAL « 0x0104011301e8 (6 bytes)
14:13:58.826 SERIAL » [ACK] (0x06)
14:13:58.829 DRIVER « [RES] [SendData]
was sent: true
14:13:58.962 SERIAL « 0x011800132300000f01cd7f7f7f7f0101030c000000010100001b (26 bytes)
14:13:58.964 SERIAL » [ACK] (0x06)
14:13:58.966 DRIVER « [REQ] [SendData]
callback id: 35
transmit status: OK, took 150 ms
repeater node IDs: 12
routing attempts: 1
protocol & route speed: Z-Wave, 9.6 kbit/s
ACK RSSI: -51 dBm
ACK RSSI on repeaters: N/A
ACK channel no.: 1
TX channel no.: 1
14:13:58.978 CNTRLR [Node 005] [~] [Binary Switch] currentValue: false => true [Endpoint 0]
14:13:59.991 SERIAL » 0x01090013050225022524c4 (11 bytes)
14:13:59.993 DRIVER » [Node 005] [REQ] [SendData]
│ transmit options: 0x25
│ callback id: 36
└─[BinarySwitchCCGet]
14:13:59.996 SERIAL « [ACK] (0x06)
14:14:00.000 SERIAL « 0x0104011301e8 (6 bytes)
14:14:00.002 SERIAL » [ACK] (0x06)
14:14:00.004 DRIVER « [RES] [SendData]
was sent: true
14:14:00.143 SERIAL « 0x011800132400000f01cd7f7f7f7f0101030c000000010100001c (26 bytes)
14:14:00.144 SERIAL » [ACK] (0x06)
14:14:00.146 DRIVER « [REQ] [SendData]
callback id: 36
transmit status: OK, took 150 ms
repeater node IDs: 12
routing attempts: 1
protocol & route speed: Z-Wave, 9.6 kbit/s
ACK RSSI: -51 dBm
ACK RSSI on repeaters: N/A
ACK channel no.: 1
TX channel no.: 1
14:14:00.262 SERIAL « 0x010b00040005032503ffcd00e2 (13 bytes)
14:14:00.265 SERIAL » [ACK] (0x06)
14:14:00.267 CNTRLR [Node 005] [~] [Binary Switch] currentValue: true => true [Endpoint 0]
14:14:00.270 DRIVER « [Node 005] [REQ] [ApplicationCommand]
└─[BinarySwitchCCReport]
current value: true
14:14:08.457 SERIAL » 0x0103003bc7 (5 bytes)
14:14:08.459 DRIVER » [REQ] [GetBackgroundRSSI]
14:14:08.463 SERIAL « [ACK] (0x06)
14:14:08.467 SERIAL « 0x0105013bb1b0c1 (7 bytes)
14:14:08.469 SERIAL » [ACK] (0x06)
14:14:08.472 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -79 dBm
channel 1: -80 dBm
2023-05-24 14:14:22.311 INFO Z-WAVE-SERVER: Client disconnected
14:14:38.457 SERIAL » 0x0103003bc7 (5 bytes)
14:14:38.467 DRIVER » [REQ] [GetBackgroundRSSI]
14:14:38.472 SERIAL « [ACK] (0x06)
14:14:38.478 SERIAL « 0x0105013bb3b1c2 (7 bytes)
14:14:38.480 SERIAL » [ACK] (0x06)
14:14:38.484 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -77 dBm
channel 1: -79 dBm
14:15:08.456 SERIAL » 0x0103003bc7 (5 bytes)
14:15:08.460 DRIVER » [REQ] [GetBackgroundRSSI]
14:15:08.469 SERIAL « [ACK] (0x06)
14:15:08.474 SERIAL « 0x0105013bb1aedf (7 bytes)
14:15:08.477 SERIAL » [ACK] (0x06)
14:15:08.480 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -79 dBm
channel 1: -82 dBm
14:15:38.447 SERIAL » 0x0103003bc7 (5 bytes)
14:15:38.449 DRIVER » [REQ] [GetBackgroundRSSI]
14:15:38.452 SERIAL « [ACK] (0x06)
14:15:38.455 SERIAL « 0x0105013bb0b1c1 (7 bytes)
14:15:38.456 SERIAL » [ACK] (0x06)
14:15:38.458 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -80 dBm
channel 1: -79 dBm
14:16:08.448 SERIAL » 0x0103003bc7 (5 bytes)
14:16:08.450 DRIVER » [REQ] [GetBackgroundRSSI]
14:16:08.457 SERIAL « [ACK] (0x06)
14:16:08.460 SERIAL « 0x0105013bb6addb (7 bytes)
14:16:08.462 SERIAL » [ACK] (0x06)
14:16:08.465 DRIVER « [RES] [GetBackgroundRSSI]
channel 0: -74 dBm
channel 1: -83 dBm
14:16:22.188 SERIAL « 0x010e0004000a063105012200e4cd00c7 (16 bytes)
14:16:22.196 SERIAL » [ACK] (0x06)
14:16:22.202 CNTRLR [Node 010] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0]
14:16:22.207 CNTRLR [Node 010] [~] [Multilevel Sensor] Air temperature: 23.3 => 22.8 [Endpoint 0]
14:16:22.213 DRIVER « [Node 010] [REQ] [ApplicationCommand]
└─[MultilevelSensorCCReport]
type: Air temperature
scale: Celsius
value: 22.8
14:16:31.090 SERIAL » 0x010a00131c032501002525dd (12 bytes)
14:16:31.093 DRIVER » [Node 028] [REQ] [SendData]
│ transmit options: 0x25
│ callback id: 37
└─[BinarySwitchCCSet]
target value: false
14:16:31.104 SERIAL « [ACK] (0x06)
14:16:31.112 SERIAL « 0x0104011301e8 (6 bytes)
14:16:31.114 SERIAL » [ACK] (0x06)
14:16:31.117 DRIVER « [RES] [SendData]
was sent: true
14:16:31.131 SERIAL « 0x011800132500000300d57f7f7f7f010103000000000201000007 (26 bytes)
14:16:31.133 SERIAL » [ACK] (0x06)
14:16:31.135 DRIVER « [REQ] [SendData]
callback id: 37
transmit status: OK, took 30 ms
routing attempts: 1
protocol & route speed: Z-Wave, 40 kbit/s
ACK RSSI: -43 dBm
ACK channel no.: 1
TX channel no.: 1
14:16:31.147 CNTRLR [Node 028] [~] [Binary Switch] currentValue: false => false [Endpoint 0]
14:16:31.156 SERIAL » 0x010a001305032501002526c7 (12 bytes)
14:16:31.157 DRIVER » [Node 005] [REQ] [SendData]
│ transmit options: 0x25
│ callback id: 38
└─[BinarySwitchCCSet]
target value: false
14:16:31.162 SERIAL « [ACK] (0x06)
14:16:31.166 SERIAL « 0x0104011301e8 (6 bytes)
14:16:31.168 SERIAL » [ACK] (0x06)
14:16:31.170 DRIVER « [RES] [SendData]
was sent: true
14:16:31.309 SERIAL « 0x011800132600000f01cd7f7f7f7f0101030c000000010100001e (26 bytes)
14:16:31.311 SERIAL » [ACK] (0x06)
14:16:31.313 DRIVER « [REQ] [SendData]
callback id: 38
transmit status: OK, took 150 ms
repeater node IDs: 12
routing attempts: 1
protocol & route speed: Z-Wave, 9.6 kbit/s
ACK RSSI: -51 dBm
ACK RSSI on repeaters: N/A
ACK channel no.: 1
TX channel no.: 1
14:16:31.326 CNTRLR [Node 005] [~] [Binary Switch] currentValue: true => false [Endpoint 0]
14:16:31.332 SERIAL » 0x010a001317032501002527d4 (12 bytes)
14:16:31.334 DRIVER » [Node 023] [REQ] [SendData]
│ transmit options: 0x25
│ callback id: 39
└─[BinarySwitchCCSet]
target value: false
14:16:31.343 SERIAL « [ACK] (0x06)
14:16:31.345 SERIAL « 0x0104011301e8 (6 bytes)
14:16:31.347 SERIAL » [ACK] (0x06)
14:16:31.348 DRIVER « [RES] [SendData]
was sent: true
14:16:31.367 SERIAL « 0x011800132700000200cd7f7f7f7f01010300000000020100001c (26 bytes)
14:16:31.369 SERIAL » [ACK] (0x06)
14:16:31.370 DRIVER « [REQ] [SendData]
callback id: 39
transmit status: OK, took 20 ms
routing attempts: 1
protocol & route speed: Z-Wave, 40 kbit/s
ACK RSSI: -51 dBm
ACK channel no.: 1
TX channel no.: 1
14:16:31.381 CNTRLR [Node 023] [~] [Binary Switch] currentValue: false => false [Endpoint 0]
14:16:31.467 SERIAL « 0x010b0004001703250300cd000f (13 bytes)
14:16:31.469 SERIAL » [ACK] (0x06)
14:16:31.471 CNTRLR [Node 023] [~] [Binary Switch] currentValue: false => false [Endpoint 0]
14:16:31.473 CNTRLR [Node 023] Scheduled poll canceled because expected value was received
14:16:31.474 DRIVER « [Node 023] [REQ] [ApplicationCommand]
└─[BinarySwitchCCReport]
current value: false
14:16:32.160 SERIAL » 0x010900131c0225022528d1 (11 bytes)
Made with ❤️ by
Daniel Lando
- Enjoying it? 
[Support me 🙏](https://github.com/sponsors/robertsLando)
AlCalzone commented 1 year ago

I know what the issue is. working on it.

thecobra666 commented 1 year ago

I know what the issue is. working on it.

Great to hear that. What is the last working release? I'm already down to 8.15.0, still does not work or is not related to zwave-js-ui?

AlCalzone commented 1 year ago

pretty sure it was broken in node-zwave-js v10.21.0. not sure which z-ui version that is right now.