Closed GoogleCodeExporter closed 9 years ago
This is the designed behavior. First make sure you have an admin account or
group of admins configured correctly. Then log into PWM with an administrative
account and close the configuration.
Original comment by menno.pi...@gmail.com
on 7 Mar 2014 at 7:46
Thanks for the reply.
wher can I set admin account for PWM management.
Original comment by man...@gmail.com
on 7 Mar 2014 at 9:49
Hi
Thanks for the reply for issue 548.
Where can I set admin user for PWM management.
Original comment by man...@gmail.com
on 7 Mar 2014 at 9:52
In the LDAP settings under the Admin Query String. This defines the search
query to find admin users. Eg. all member of group pwmAdmins:
(memberOf=cn=pwmAdmins,cn=groups,dc=example,dc=com)
The exact query depends on your setup and group membership attribute.
You could also filter on an (extended schema) attribute:
(pwmPermissions=admin)
Original comment by menno.pi...@gmail.com
on 7 Mar 2014 at 10:06
Thanks a ton, now my pwm setup is fully functional.
Is there any plugin available or way out to integrate pwm url at windows login
prompt/screen, so that incase of password reset user need not to use other
machine or logon locally?
Regards
Mangesh
Original comment by man...@gmail.com
on 10 Mar 2014 at 10:23
Original issue reported on code.google.com by
man...@gmail.com
on 7 Mar 2014 at 7:28