**Describe the problem you have/What new integration you would like**
Support for the Sensirion SHT1x temperature/humidity sensors
**Please describe your use case for this integration and alte…
-
Link: http://www.john.geek.nz/2012/11/update-reading-data-from-a-sensirion-sht1x-with-a-raspberry-pi/
-
I've been trying to get an SHT10 to work on a moteino (http://lowpowerlab.com/moteino/) which works at 3.3v and 8Mhz, but the readings all come back weird (-40c,-40f, and -4.6%). Is there something t…
zippy updated
8 years ago
-
Hello, I'm a user of Arduino in China. When I was using SHT1x.h in Arduino 1.0.1, there was an "Ack Error 1" error, which is all right in Arduino 1.0 and earlier version. I can't fix it by myself. So …
-
Sensors after v3 use a new set of more 'optimised' coefficients. The lib only uses the old ones.
New coefficients
C1 = -2.0468;
C2 = 0.0367;
C3 = -0.0000015955;
relevant lines 82 to 84 in S…
cenau updated
8 years ago
-
Hi all!
I'm not sure whether is an issue, but I'm using the library together with a modem sleep. Basically the code runs for 4.5 minutes in modem sleep and then it connects to the wifi and transmit…
-
Version 5 of the SHT1x Datasheet (December 2011) uses different constants than the ones shown here. In SHT1x.cpp, the corrections are as follows.
For 5V and temperature in Celsius, D1 = -40.1
For 5V …
-
hello,
I am a beginner and I wanted to use your program for this humidity and temperature sensor (Sensirion SHT31) without connecting it in I2C which blocks.
It should be able to work with the code…
-
Currently, the JSON API has a lot of issues
- [x] Measurements are not nested into a "sensors" JSON object, so it's hard to figure out an unknown configuration key from an unconfigured sensor.
- [x]…
-
Please give it a try with CoolCave. manually stop actor 3 (led is lit since it's a inverted actor) and now activate Actor 6.
Result:
CoolBoard receives message and answers: