Tasks:
1. Measure actual flow rate of the gravity powered system by timing water exiting the effluent
2. Check if the flow rate is at 0.76 mL/s
3. Adjust the height if the flow rate does not agree …
-
It looks like certain min and max depths can cause an IndexError when searching for corresponding sedimentation rates as an AgeDepthModel runs `self.fit()`. This is for v0.0.5 and likely previous vers…
brews updated
5 years ago
-
@monroews
Hi Monroe, after we restarted the computer for required updates today, we found that the ProCoDa states (i.e. turbidity target, PID control constants, turbidimeters, etc.) were all cleared…
-
Some suggestions:
- run an experiment overnight (>12 hrs) to generate floc blanket
- see how long it takes to generate floc blanket
- clean out algal growth in flocculator
Standardize experiment…
-
Run experiments varying the upflow velocity through the sedimentation tube and analyze results to measure removal efficiency and obtain an optimal upflow velocity
-
Suggest creating a new term for Loinc: 7797-4 [Rouleaux [Presence] in Blood by Light microscopy]
New term label:
New term comment (if any):
Your biocurator ID for loinc2hpo (if desired): HPO:probinso…
-
1. The team decided to have influent turbidity of 100, not 10.
2. Our main goal measurement will be headloss before and after the flocculator instead of comparing the influent and effluent turbidity,…
-
A User submitted this inquiry:
> VBET tool for riparian zones in Western Australia
Hi Joe,
I am trying to use the VBET tool (using ArcMap 10.6) to derive a riparian zone for the Avon River…
-
February 15th, 2018
Experiment with flipped contact chamber with 76 rpm water, 20 rpm coagulant for 15 minutes
-
During the meeting with Monroe, we decided to try to make a smaller and shorter sedimentation tank for our experiment. Since we have such a low concentration of clay, it takes too much time to actuall…