Refs #10
- [x] https://github.com/bluesky/ophyd/blob/master/ophyd/areadetector/detectors.py - verify that implementation of Eiger in Ophyd Areadetector is complete
- [x] https://github.com/NSLS…
-
See e.g. https://github.com/cctbx/cctbx_project/commit/66a61bad32a054d0a7c52b4fe3237b3a04406967 and conversation, ongoing work
-
Underlying bug in dxtbx -
```
DATASET "omega" {
DATATYPE H5T_IEEE_F64LE
DATASPACE SIMPLE { ( 3 ) / ( 3 ) }
DATA {
(0): 0, 45, 90
…
-
In a CHX scan by using Eiger detector, we usually make count number=1 and large image number/per count (for example 10,000). When we use get_table( db[uid]) to get scalars, we only get one number of s…
-
One current performance bottleneck in Artemis is arming the detector. This requires setting a number of properties through odin then waiting for the stale parameters to be complete. We should analyse …
-
When running as user, there are permission issues when writing and saving logfiles to `/dls_sw/i24/logs/`.
Also, as the eiger software can't make directories and users don't have permission to create…
-
At the moment it is assumed that the files which belong to foo_master.h5 must be foo_data_0000nn.h5 or foo_0000nn.h5 - this is not necessarily true.
This is particularly not true if the data are vi…
-
At CHX, we met a problem that the function get_image (/opt/conda_envs/analysis/lib/python3.5/site-packages/databroker/pims_readers.py) can't open some files recorded by Eiger4M detector. We knew tha…
-
1.
```
# Get the trusted range of pixel values
underload = (
float(nx_detector.handle["underload_value"][()])
if "underl…
-
Could clobber it down to 16 bits for the calculation but a lot of example data are recorded with an exposure time with an Eiger which allows 32 bit readout. In the cases I looked at the data would fit…