Hi there,
I've created a patch to implement the following ni-DAQmx read property calls:
DAQmxGetReadRelativeTo() --> task.get_read_relative_to()
DAQmxSetReadRelativeTo() --> task.set_read_relati…
-
Might be a good idea to eliminate one dependency. Maybe fork PyDAQmx and modify to make syntax similar?
-
At the moment the OrcaFlash waits for a certain amount of milliseconds in the Start method before really starting with the acquisition. However, it sends already a start to the observers (daqmx).
The…
-
Hi,
Following the Task example given at http://pythonhosted.org/PyDAQmx/usage.html#task-object, I am trying to do:
```
from PyDAQmx import *
analog_input = Task()
analog_input.CreateAIVoltageChan("D…
-
Having a strange issue with ccall on windows 7 (64bit, Julia 0.2). I am using a National Instruments data acquisition card and try to call a function of the API via ccall
(http://zone.ni.com/reference…
-
Hello,
I have ReadAnalogF64 working, but with WriteAnalogF64 I'm having trouble with argument 2 (autostart, bool32). I've tried PyDAQmx.bool32(True) (or False) as well as ctypes.c_ulong(1), etc., and …
-
Hi,
after I used the wizard to configure the galvo-frame scan configuration (I followed the wiki for all the components) when I launch helioscan this is the error message I got:
![error message_2013…
-
Loading a TDMS file generated with NI-DAQmx with the following
``` python
from nptdms import TdmsFile
tdms_file = TdmsFile("example.tdms")
```
Gives the following error
``` python
Traceback (most r…
-
Agabi: Apparently I am not able to drive the pockel cell intensity modulation at all using HelioScan in any ImagingMode. So, I try out with a separate Labview code which is able to drive the pockel ce…
-
With the 3D FPGA config the shutter is supposed to be driven on DO 1 of the FLex RIO adapter card. However, there is no signal coming from here. What I have done however is to create a separate digita…