Good day.
While running the launch file the following error appears:
`Error Sopas answer mismatch: Error unexpected Sopas answer for request sWN LMP
outputRange 0x00 0x01 0x00 ..., received ans…
-
Hello,
I am getting the following errors when running the C++ minimum_sick_scan_api_client with our LRS4000 (Firmware version
1.6.0.25R)
```
[Error]: Read Error when getting datagram: 1
[Erro…
-
Sopas: devicestatus 35 Device contaminated,warning threshold reached-Please clean front screen
Sending : sRN SCdevicestate
Receiving: sRA SCdevicestate 0 or sRA SCdevicestate 1
I tried, but th…
hoopp updated
3 months ago
-
Encoder settings for for LMS1xx, LMS5xx, LMS4000, LRS4000 need to be updated:
![image](https://github.com/SICKAG/sick_scan_xd/assets/46743496/489a6396-8f64-4090-9e98-43b828605b53)
-
Hi,
We're facing continuous data interruption issue with ASCII protocol on TIM-240(see the picture below), and it's suggested to change to binary protocol to prevent this issue, but now it's burden…
-
I have a sensor which outputs data continuously every 7 ms. I know this is accurate because I am using the same sensor on a PC and the message comes from the sensor every 7 ms.
I modified one of y…
-
LRS4xxx configuration of scan rate, angular resolution, min and max angle and frame id is partially missing in the launch file.
-
Hi,
while trying to get scan data from the LRS4000 using the sick_lrs_4xxx.launch I got the following error
` Error Sopas answer mismatch: Error unexpected Sopas answer for request sWN LMPoutputR…