smea sampler experiments for a1111 webui
These sampler has nothing to do with NAI's sampler or Euler sampler, I'm just suck at naming them.
(smea here stands for "Shovel More Extra Artifacts")
originally created by Koishi-Star and ananosleep
TCD sampler from dfl
RECOMMEND: Use: Smea mbs2 (#) / Smea mds2 (#) / h max (#) / Max(2b/3c/4b), they add details (or artifacts) more reliably
Also check Dynamic Thresholding, you can add more details
Euler Dy: og Euler Dy with DPM2 tweak, toggle on/off every step
Euler Smea: og Euler Smea Dy with DPM2 tweak, use smea sampling only, toggle on/off every step
Euler Smea Dy: og Euler Smea Dy with DPM2 tweak, loopping scale up > folded to 1/2 size > normal >... every step
Euler Smea dyn a: Euler Smea with DPM2 tweak (less sigma), toggle on/off (scale up) every step every step
Euler Smea dyn b: Euler Smea with DPM2 tweak (less sigma), loopping scale down > up > normal >... every step
Euler Smea dyn c: Euler Smea with DPM2 tweak (less sigma), toggle on/off (scale down) every step every step
Euler Smea md: Euler Smea with DPM2 tweak (less sigma), start with Smea mc then toggle Smea mb on/off every step, ended with Smea ma
all sampler above stopped smea / dy sampling at 1/3 total steps
Euler Smea Max: Euler Smea with adjusted cosine wave scaling
Euler Smea Max s: Euler Smea Max with smoothed latent in process
Euler Smea ma: Euler Smea with DPM2 tweak (less sigma), combine scaled up latent image with normal one
Euler Smea mb: Euler Smea with DPM2 tweak (less sigma), combine scaled up and scaled down latent image with normal one
Euler Smea mc: Euler Smea with DPM2 tweak (less sigma), combine scaled down latent image with normal one
Euler Smea mas: Euler Smea ma tweaked
Euler Smea mbs: Euler Smea mb tweaked
Euler Smea mcs: Euler Smea mc tweaked
Euler Smea mds: Euler Smea md tweaked
Euler Smea mbs2: Euler Smea mds with tweaked sigma
Euler Smea mds2: Euler Smea mds with tweaked sigma
Euler Smea mbs2 s: Euler Smea mbs2 with smoothed latent in process
Euler Smea mds2 s: Euler Smea mds2 with smoothed latent in process
Euler Smea mds2 max: Euler Smea mds2 with adjusted cosine wave
Euler Smea mds2 s max: Euler Smea mds2 s with adjusted cosine wave
all sampler above stopped smea sampling at 1/6 total steps
Euler Max: from ananosleep's repo
Euler h max (#): Euler Max with adjusted cosine wave
Euler Max(#): Euler Max with adjusted cosine wave
Euler Dy koishi-star: og Euler Dy made by koishi-star
Euler Smea Dy koishi-star: og Euler Smea Dy made by koishi-star
TCD / TCD Euler a: from dfl's repo
The reason of many experiments is due to og sampler tends to blurred the background or overfry the image,
so I checked DPM2 sampler and experiment if it's worth to tweak it
What Smea sampling do is scaling latent image > denoise > scale it back to original size
What dy sampling do is shrinking latent image to 1/2 size > denoise > extend it to original size
since what they did is bascially just scaling latent image, I use smea sampling only
What all these samplers do is bascailly trying to combine different scaled latent image to denoise image to generate better details (artifacts)