Bed leveling bug, please update new branch of firmware 1.2.8 #3

Open Sv3nergie opened 6 years ago

Sv3nergie commented 6 years ago

adjustments to the individual probe points are not stored, when changes are made a fixed value is set and the whole bed leveling is messed up. When fixed, is it possible to update this github branch please.

alexnv commented 6 years ago

Figured out what is the problem with the sensor, in the firmware confused type of sensor contact, instead of normal-closed specified normally-open (or Vice versa)

Sv3nergie commented 6 years ago

No, my problem is not sensor related, thats ok. It's adjusting those points that don't work. It is fixed in the hex file you can flash from the anycubic site (version 1.2.8). But I like tmc drivers and need the 1.2.8 version in marlin code please. Can u please upload sources Anycubic ?

jsprinceiii commented 6 years ago

I also asked via support. Was told maybe soon. anycubic-marlin-128_support