Ticket Submitted via Website #307

Closed fire-bot closed 2 years ago

fire-bot commented 2 years ago

Sent by (mkakasapu@gmail.com). Created by fire.


Koen created a ticket

Name: Koenvan Bockhooven

Email: k.v.bockhooven@quicknet.nl

Timezone: 1

Software: CommandStationEx

Version: 3.0.0

Title: Error 308 from PT

Description: I have installed DCC++EX version 3.1 and this works fine with Rocrail and JMRI. Except for the program track. I get error 308, no response, in Decoder Pro. In the Arduino monitor I get the following: ACK baseline=0/0mA Threshold=20/59mA Duration between 4000us and 8500us > < VB cv=29 value=0 > < NO-ACK after 148mS max=1/2mA pulse=0uS samples=155 gaps=0 > < V0 cv=29 bit=7 > < NO-ACK after 145mS max=1/2mA pulse=0uS samples=72 gaps=0 > < V1 cv=29 bit=7 > < NO-ACK after 141mS max=1/2mA pulse=0uS samples=36 gaps=0 > < Auto JOIN > < Callback(-1) > < ACK baseline=0/0mA Threshold=20/59mA Duration between 4000us and 8500us > < VB cv=29 value=0 > < NO-ACK after 148mS max=1/2mA pulse=0uS samples=160 gaps=0 > < V0 cv=29 bit=7 > < NO-ACK after 145mS max=1/2mA pulse=0uS samples=75 gaps=0 > < V1 cv=29 bit=7 > < NO-ACK after 141mS max=1/2mA pulse=0uS samples=37 gaps=0 > < Auto JOIN > < Callback(-1) > < ACK baseline=0/0mA Threshold=20/59mA Duration between 4000us and 8500us > < VB cv=29 value=0 > < NO-ACK after 148mS max=1/2mA pulse=0uS samples=160 gaps=0 > < V0 cv=29 bit=7 > < NO-ACK after 143mS max=1/2mA pulse=0uS samples=75 gaps=0 > < V1 cv=29 bit=7 > < NO-ACK after 142mS max=1/2mA pulse=0uS samples=38 gaps=0 > < Auto JOIN > < Callback(-1) > Whatever I try (several loco's, different motor shield, different powersupply) or settings I change (ACK LIMIT, ACK MIN, MAX values) the error persists. When I set <1 JOIN> the loco reacts to the throttle setting normally. Any suggestions?

Remaining email Quota: 99

Asbelos commented 2 years ago

The symptoms suggest that the current measurement on the prog track is not working. 1 JOIN working confirms that the dcc signal is getting to the track through the prog side of the motor shield.

What shield are you using and what setting do you have in the config.h ?