issues
search
Industry4
/
MultiPlug.Ext.Hermes
MultiPlug IPC HERMES 9852 Extension used for the transfer of PCB related data between manufacturing equipment on a electronics assembly line.
https://www.smema-hermes-gateway.app
4
stars
1
forks
source link
Handle Downstream Transfer States
#118
Open
Industry4
opened
2 months ago
Industry4
commented
2 months ago
Similar to #80 handle the Downstream Transfer State of
Incomplete
and
Not Started
.
Issue
The Transfer State is ignored and waits for the SMEMA Board Available to go low (Board Departed/Transferred)
This can create a Hermes Lockup (wait) until the SMEMA state goes low. ('
Transpport Finished
' will not be sent until SMEMA goes low.
Design
User prompts:
The Digital Twin Board Data may have to be moved from Downstream back to This Station, if the
Transport Finished
has been already sent (SMEMA low)
OR, User prompt to send '
Transport Finished
', then resend
Board Available
Message to reset the transfer.
Either way, the operator should be made aware of the bad transfer.
Issue
Design