Simple plugin to manage Heishamon through MQTT
This Domoticz plugin is able to read and to control the Panasonic using the Heishamon module.
To use Plugins in Domoticz please read : https://www.domoticz.com/wiki/Using_Python_plugins
SetHeatpump Set heatpump on or off 0=off, 1=on tested
SetHolidayMode Set holiday mode on or off 0=off, 1=on not tested
SetQuietMode Set quiet mode level 0, 1, 2 or 3 tested
SetPowerfulMode Set powerful mode run time in minutes 0=off, 1=30, 2=60 or 3=90 tested
SetZ1HeatRequestTemperature Set Z1 heat shift or direct heat temperature -5 to 5 or 20 to max tested
SetZ1CoolRequestTemperature Set Z1 cool shift or direct cool temperature -5 to 5 or 20 to max not tested
SetZ2HeatRequestTemperature Set Z2 heat shift or direct heat temperature -5 to 5 or 20 to max not tested
SetZ2CoolRequestTemperature Set Z2 cool shift or direct cool temperature -5 to 5 or 20 to max not tested
SetOperationMode Sets operating mode 0=Heat only, 1=Cool only, 2=Auto, 3=DHW only
, 4=Heat+DHW, 5=Cool+DHW, 6=Auto+DHW not tested
SetForceDHW Forces DHW (Operating mode should be firstly set to one with DWH mode (3,4,5 or 6) to be effective. Please look at SET9 ) 0, 1 not tested
SetDHWTemp Set DHW target temperature 40 - 75 not tested
SetForceDefrost Forces defrost routine 0, 1 not tested
SetForceSterilization Forces DHW sterilization routine 0, 1 not tested
SetZones Set zones to active 0 = zone 1 active, 1 = zone2 active, 2 = zone1 and zone2 active tested
If you don't see the heishamon values in domoticz after enabling the plugin there are a few things you should check:
Version 0.1.1 -> First version
Version 0.1.2 -> Added COP devices and Error (Text)
Version 0.1.3 ->
- Round Set...RequestTemperature and SetDHWTemp
- check Set...RequestTemperature to be in range -5 to 5 and 20 to max (max is user variable maxTemp, default=50)
- Check SetDHWTemp to be in range 40 to 75
- Force_DHW_State only on/off (no unknown anymore)
Version 0.1.4 -> Fix: Switch only publish On (1) not Off (0) in MQTT
Version 0.1.5 -> Implemented S0 Support (2 devices)
Version 0.1.6 -> No change
Version 0.1.7 -> Use MQTT for S0 (panasonic_heat_pump/s0/Watt/x)
Version 0.1.8 -> Allow mqtt base topic to be set
Version 0.1.9 -> Heishamon v1.0 + Zone (for older version of Heishamon take 0.1.8)
Version 0.2.0 ->
- Change Error from Text to Alert
- Add Heat Pump Model
- Add Pump Duty -
Version 0.2.0 ->
- Added WattHourTotal to S0 (General,kWh)
- Added Defrost Counter
- Detect old Heishamon Firmware
- Code cleanup