An iobroker adapter for a LG ESS hybrid inverter. With this adapter, the status of the inverter can be read. It is also possible to operate the inverter.
Configuration
Getting the password
Possibility Number 1
The password is the MAC address of the LAN interface of the ESS in lower case and without :.
The MAC address can be read in the Fritzbox (or other router). (Thanks riessfa)
Possibility Number 2
- Download the file LG_Ess_Password.exe
- Connect the computer to the WLAN of the LG_ESS system. (WLAN password is on the type plate)
- Start LG_Ess_Password.exe (At least .Net Framework 4.5 required)
- Make a note of your password
Possibility Number 3
For those, who don't like exe: (Thanks grex1975)\
you can use any REST Client to get the password:
- connect to the WLAN of the LG_ESS
- Execute a POST request\
Url: https://192.168.23.1/v1/user/setting/read/password \
Headers: "Charset": "UTF-8", "Content-Type": "application/json"\
{Body: "key": "lgepmsuser!@#"}
This should give you the password and a status in return.
Changelog
WORK IN PROGRESS
- (Morluktom) Bugfix: State value to set for "lg-ess-home.0.user.essinfo.home.statistics.bat_status" has to be type "number" but received type "string"
- LG ESS HOME 15 Plus added
0.3.0 (2024-08-10)
- (Morluktom) Fixed warnings found by adapter checker
- (Morluktom) Added Admin 5 configuration
- (Morluktom) Added Ukrainan language
- (Morluktom) Add PV Forecast to chart
- (morluktom) NodeJS >= 18.x and js-controller >= 5 is required
0.2.3 (2022-04-05)
- (Morluktom) Chart widget: Datepicker changed to jquery
0.2.2 (2022-04-04)
- (Morluktom) Chart widget updated
0.2.1 (2022-04-04)
- (Morluktom) Chart widget updated
0.2.0 (2022-03-14)
- (Morluktom) Chart widget added
0.1.1 (2022-01-07)
- (Morluktom) replaced deprecated library and login as installer only when needed
0.1.0 (2021-11-27)
- (Morluktom) Read chart data and data from the installer settings
0.0.10 (2021-05-04)
- (Morluktom) Bugfix boolean value
0.0.9 (2021-05-04)
- (Morluktom) Bugfix boolean value
0.0.8 (2021-02-06)
0.0.7 (2021-02-01)
0.0.6 (2020-12-23)
- (Morluktom) Data type recognition fixed
0.0.5 (2020-12-15)
- (Morluktom) ScalingFactor moved to nativ
- password encryption => auto encryption (Maybe you have to set the password new)
0.0.4
- (Morluktom) W => kW, values confirmed
0.0.3
- (Morluktom) Structure of the channel and states changed
0.0.2
- (Morluktom) Separate Intervall for Common and Home
0.0.1
- (Morluktom) initial release
License
MIT License
Copyright (c) 2024 Morluktom strassertom@gmx.de
Permission is hereby granted, free of charge, to any person obtaining a copy
of this software and associated documentation files (the "Software"), to deal
in the Software without restriction, including without limitation the rights
to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
copies of the Software, and to permit persons to whom the Software is
furnished to do so, subject to the following conditions:
The above copyright notice and this permission notice shall be included in all
copies or substantial portions of the Software.
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE
SOFTWARE.