Remotec Technology
This app adds support for devices made by Remotec Technology.
Links:
Remotec Technology Athom apps
Remotec Technology Github repository
Supported devices:
Remotec Scene Master ZRC-90 (BW8510) (Homey ≥ 1.3.0 required)
With the Remotec Scene Master ZRC-90 it is possible control any other devices (including non-Zwave) or set states / variables via Homey's flows.
The following triggers are supported:
- Button Pressed 1x
- Button Pressed 2x
- Button held down (5x per second report)
- Button released
- Any button pressed (including tokens)
The following conditions are supported:
- Battery alarm activated | Battery in healthy condition
Note: All commands will be send to Homey. With this device it's not possible to associate buttons to other devices to control them directly (without Homey).
Remotec ZXT-120 Z-Wave-to-AC IR Extender (BW8366)
The following capabilities are supported:
- Temperature measurement
- Thermostat Mode
- Thermostat Target Temperature (setpoint)
- Thermostat Fan Speed Mode
- Thermostat Fan Swing Mode
- Thermostat On-Off
- Battery capabilities (measure and alarm)
Remotec ZXT-600 AC Master (BW8490)
The following capabilities are supported:
- Temperature measurement
- Thermostat Mode
- Thermostat Target Temperature (setpoint)
- Thermostat Fan Speed Mode
- Thermostat Fan Swing Mode
- Thermostat On-Off
- Battery capabilities (measure and alarm)
Supported Languages:
Feedback:
Any requests please post them in the Remotec app topic on the Athom Community Forum or contact me on Slack
If possible, please report issues at the issues section on Github otherwise in the above mentioned topic.
Changelog:
v2.2.4
fix
- Fix issue app crashing while using the 'Set Fan “SWING” mode' action card
- Update Homey meshdriver to 1.2.30
v2.2.3
fix
- Fix issue where custom icons are not shown in Homey v2.0.0
- Migrated to Homeycompose funtion (DEV only)
update:
- Update Homey meshdriver to 1.2.28
open issues:
- Only 1 picker (Thermostat mode) is shown in Homey v2.0.0, Fan mode is not shown
v2.2.2
fix
- Fix issue with ZXT-120 and ZXT-600 blocking settings to be updated
v2.2.1
- Add support (productTypeID's) for all devices for the following regions: US, EU, AU, IL, JP, CN
- Add link to Remotec app topic on community.athoms.com
- Add polling interval setting for temperature measurements for ZXT-120
- Restructure device settings ZXT-120 and ZXT-600
fix
- Fix issue with ZXT-120 temperature correction parameter number
- Improve inclusion instructions for ZRC-90
update:
- Update Homey meshdriver to 1.2.25
v2.2.0
- Add full support for ZXT-600
- Extended ZXT-120 implementation to full support (all options, including fan mode)
- Major update for ZXT-120 driver / settings / polling intervals: re-inclusion of ZXT-120 is advised
- Add flow action cards supporting to set the Thermostat Mode, specific (mode based) Thermostat setpoints, Fan Speed Mode and Fan Swing mode
fix
- Unable to set setpoint in cooling mode
update:
- Update Homey meshdriver to 1.2.23
v2.1.2
fix
- Fix temperature commands not responding on certain AC models
v2.1.1
fix
- Fix issue with non-registered flow card of ZXT-120
v2.1.0
- Add initial support for the ZXT-120 Z-Wave-to-AC IR Extender (temperature and mode control)
fix
- Fix issue where the battery alarm condition card cause the app to crash (flow rebuilding required)
update:
- Update Homey meshdriver to 1.2.8
- Add link to Homey community forum topic
Future work:
Add generic trigger card for 'A button has been pressed' together with tokens
- ZRC-90 add option to disable re-triggering when a button is held
- ~ add ZXT-120 Z-Wave-to-AC IR Extender ~
- ~ add ZXT-600 Z-Wave-to-AC IR Extender ~