bcattoor / NovaPoint-Open-Issue-List

Open transparant, and available for everyone.
0 stars 0 forks source link

Novapoint Railway: Draw Longprofile: Styles #6

Closed bcattoor closed 6 years ago

bcattoor commented 7 years ago

Context

When using the new feature to add the distance between project (Z), and the calculated terrain (z) to a long profile, the value's of the project-z are wrong. We have already been asking for this feature for quite a while now.

Information

Name Value
Software version NVP 20.05FP3b
Software version AutoCAD 2017
Module name ea: RAILWAY
OS Windows 7
Vianova tracking number 847426 + 8320

Wanted Behaviour

When using the long-profile style Belgium.Railway.DeltaZ value's of delta Z are wrong.

Actual Behaviour

When using the long-profile style Belgium.Railway.DeltaZ value's of delta Z should be calculated with reference to the right terrain value.

Steps to Reproduce

Use style, see error ...

Context

Because this “feature” does not work, our designers loose day's of work manually adjusting z value's all over. Manually adjusting results leads to typing errors which cost money ...

bcattoor commented 7 years ago

Vianova support BE:

Problem will be fixed in next release.

bcattoor commented 6 years ago

A new release is at hand.

It has been confirmed, a fix is provided in the new version. (NP20.0x FP4)