cmsdaq / DAQExpert

New expert system processing data model produced by DAQAggregator
1 stars 2 forks source link

Special instructions: PIXEL repeatedly in sof error recovery #196

Closed gladky closed 6 years ago

gladky commented 6 years ago
  • Pixel
    • when pixel goes repeatedly in SoftErrorRecovery check DCS. If problem in DCS (sectors turned off) ask DCS shifter to call Pixel DOC. If no problem in DCS call Pixel DOC immediately.
gladky commented 6 years ago
  1. is this up to date?
  2. shall we include this into expert?
andreh12 commented 6 years ago

on 2.: it's already implemented, see https://github.com/cmsdaq/DAQExpert/blob/54b535439131c3b05115695d38e3375009e1c081/src/main/java/rcms/utilities/daqexpert/reasoning/logic/failures/fixingSoftErrors/ContinouslySoftError.java#L41-L43

gladky commented 6 years ago

Thank you @andreh12 I missed that. Let's wait for PIXEL experts to confirm that it's up to date. Later I will move it to the section "Covered by Expert"

gladky commented 6 years ago

up to date - confirmed by PIXEL