Closed gladky closed 6 years ago
Currently in expert it would be identified as FED stuck and default recovery suggestion would be proposed:
- StopAndStartTheRun with <<RedRecycle::{{SUBSYSTEM}}>> and <<GreenRecycle::{{SUBSYSTEM}}>> (try up to 2 times)
- Problem fixed: Make an e-log entry. Call the DOC of the subsystem {{SUBSYSTEM}} to inform
- Problem not fixed: Call the DOC for the subsystem {{SUBSYSTEM}}
Description of the problem:
TTCP {{TTCP}} of {{SUBSYSTEM}} subsystem is blocking triggers, it's in {{TTCPSTATE}} TTS state, The problem is caused by FED {{FED}} in {{FEDSTATE}}
Note that:
We can add this as a special instruction for HCAL that distinguishes stable-beams and non-stable-beams, but please answer following questions:
contacted HCAL experts
I do not think that we need any special instructions for the case when HCAL blocks the run. This was probably left over from last year and should not be needed anymore
Then we just have to remove the instructions.
removed