issues
search
danielmcmillan
/
irrigation-system
[In progress] Hardware and software for irrigation control and monitoring
MIT License
0
stars
0
forks
source link
issues
Newest
Newest
Most commented
Recently updated
Oldest
Least commented
Least recently updated
Remove controller unit property detail messages
#41
danielmcmillan
opened
5 months ago
0
When configuring controller unit with no remote units, the config doesn't get stored
#40
danielmcmillan
opened
5 months ago
0
Support null/missing property values
#39
danielmcmillan
closed
5 months ago
1
Control processor can mix up remote unit command results waiting in serial buffer
#38
danielmcmillan
opened
7 months ago
0
Read sensor value asynchronously
#37
danielmcmillan
closed
7 months ago
1
Detect disconnected solenoid
#36
danielmcmillan
opened
7 months ago
0
Remote unit voltage converter issue with COMP capacitor
#35
danielmcmillan
opened
7 months ago
0
Controller events are sometimes missed on MQTT
#34
danielmcmillan
closed
7 months ago
1
Don't configure RF module when no zones configured
#33
danielmcmillan
closed
7 months ago
0
Proper handling of remote unit error responses
#32
danielmcmillan
opened
8 months ago
0
Verifying property updates in the cloud
#31
danielmcmillan
opened
8 months ago
0
Testing with simulated remote units
#30
danielmcmillan
opened
8 months ago
0
Improve controller unit responsiveness with multitasking
#29
danielmcmillan
opened
8 months ago
1
When writing invalid config, control unit keeps restarting until hard reboot
#28
danielmcmillan
closed
7 months ago
1
When sending invalid MQTT topic, it gets stuck in infinite loop
#27
danielmcmillan
closed
8 months ago
0
After configuring control unit, remote unit update may not be scheduled immediately
#26
danielmcmillan
closed
7 months ago
1
Investigate control processor Modbus communication issues
#25
danielmcmillan
opened
9 months ago
0
Support sensor at remote unit with RS485 interface
#24
danielmcmillan
closed
10 months ago
0
Updated remote unit hardware
#23
danielmcmillan
closed
10 months ago
3
Better handling of timing out remote unit
#22
danielmcmillan
opened
1 year ago
0
When desired value changes twice in same batch of events, UI is stuck showing spinner
#21
danielmcmillan
opened
1 year ago
0
Authentication
#20
danielmcmillan
closed
5 months ago
0
Send remote unit available change event after every contact
#19
danielmcmillan
closed
7 months ago
0
Some active solenoids have repeated on status events
#18
danielmcmillan
closed
7 months ago
1
Config validation
#17
danielmcmillan
opened
1 year ago
0
Improve remote unit update and retry scheduling
#16
danielmcmillan
closed
7 months ago
2
When updating config, if motor relay is on it gets turned off
#15
danielmcmillan
opened
1 year ago
0
Scheduling
#14
danielmcmillan
opened
1 year ago
0
Alert notifications
#13
danielmcmillan
opened
1 year ago
0
Monitoring status in cloud
#12
danielmcmillan
closed
5 months ago
0
Support config to disable Vacon Fieldbus monitoring
#11
danielmcmillan
closed
1 year ago
1
Indicate controller unit status with LED
#10
danielmcmillan
closed
8 months ago
1
Refactoring after controllers consolidation
#9
danielmcmillan
opened
1 year ago
0
Invalid controller command for remote unit causes controller crash
#8
danielmcmillan
closed
8 months ago
0
Controller commands interface is unreliable
#7
danielmcmillan
closed
7 months ago
2
Updated controller unit hardware
#6
danielmcmillan
closed
9 months ago
2
New UI
#5
danielmcmillan
opened
1 year ago
0
Remote unit configuration UI
#4
danielmcmillan
opened
1 year ago
0
Update control processor design documents
#3
danielmcmillan
opened
1 year ago
0
Buffer overflow in event history data structure
#2
danielmcmillan
closed
1 year ago
3
Visibility of historical values
#1
danielmcmillan
closed
5 months ago
0