When math is enabled CH1 and CH2 waveforms are not visible #93

Open Tiziano-Bielli-EE opened 6 months ago

Tiziano-Bielli-EE commented 6 months ago

Hi, I tried searching for this, but I couldn't find anything: when I enable math for CH1 and CH2 (for example CH1*CH2) only the math waveform is shown. Usually it isn't an issue but for some measurements (power) would be useful to show all three waveforms. I tried OWON software and it's showing all three waveforms so it should be easy to add a small check box to enable/disable this option.

Or even better you could consider the math channel as a third channel so it's always at hand reach.

Another possible feature for math would be to make the voltage/div a bit smarter by calculating its value automatically (only when you change math operations): for example, you if you set CH1CH2 it automatically sets MathDiv = CH1Div CH2Div ...