Illegal value of 70 degrees is reported #131

Closed Patrick-999 closed 3 months ago

Patrick-999 commented 3 months ago

I get an error on each status update:

[homebridge-melcloud-control] This plugin generated a warning from the characteristic 'Heating Threshold Temperature': characteristic was supplied illegal value: number 70 exceeded maximum of 60. See https://homebridge.io/w/JtMGR for more info.

However, my heat pump does allow water to be 70 degrees.

grzegorz914 commented 3 months ago

please post the debug log in plugin settings advanced settings>>>system>>debug enable it restart plugin and get the log

Patrick-999 commented 3 months ago

[8/6/2024, 4:05:24 PM] [homebridge-melcloud-control] Heat Pump, Hus, debug: Account Info: { "ContextKey": "removed", "Client": "removed", "Terms": 1301, "AL": 1, "ML": 0, "CMI": true, "IsStaff": false, "CUTF": false, "CAA": false, "ReceiveCountryNotifications": false, "ReceiveAllNotifications": false, "CACA": false, "CAGA": false, "MaximumDevices": 10, "ShowDiagnostics": false, "Language": 18, "Country": 217, "RealClient": 0, "Name": "removed", "UseFahrenheit": false, "Duration": 525600, "Expiry": "2025-08-06T13:55:08.467", "CMSC": false, "PartnerApplicationVersion": null, "EmailSettingsReminderShown": true, "EmailUnitErrors": 0, "EmailCommsErrors": 0, "ChartSeriesHidden": 0, "DeletePending": false, "Throttle": true, "IsImpersonated": false, "LanguageCode": "sv", "CountryName": "Sverige", "CurrencySymbol": "kr", "SupportEmailAddress": "support@se.mee.com", "DateSeperator": "/", "TimeSeperator": ":", "AtwLogoFile": "ecodan_logo.png", "DECCReport": false, "CSVReport1min": false, "HidePresetPanel": false, "EmailSettingsReminderRequired": false, "TermsText": null, "MapView": false, "MapZoom": 21, "MapLongitude": "removed", "MapLatitude": "removed", "Throttled": false, "ClientId": "removed" } [8/6/2024, 4:05:24 PM] [homebridge-melcloud-control] Heat Pump, Hus, debug: Device Info: { "DeviceID": 116257407, "DeviceName": "Hus", "BuildingID": 814404, "BuildingName": null, "FloorID": null, "FloorName": null, "AreaID": null, "AreaName": null, "ImageID": -9, "InstallationDate": "2022-12-31T00:00:00", "LastServiceDate": "2022-12-31T00:00:00", "Presets": [], "OwnerID": 1048479, "OwnerName": null, "OwnerEmail": null, "AccessLevel": 4, "DirectAccess": false, "EndDate": "2500-01-01T00:00:00", "Zone1Name": null, "Zone2Name": null, "MinTemperature": 0, "MaxTemperature": 40, "HideVaneControls": false, "HideDryModeControl": false, "HideRoomTemperature": false, "HideSupplyTemperature": false, "HideOutdoorTemperature": false, "EstimateAtaEnergyProductionOptIn": false, "EstimateAtaEnergyProduction": false, "BuildingCountry": null, "OwnerCountry": null, "AdaptorType": 3, "LinkedDevice": null, "Type": 1, "MacAddress": "8c:53:e6:30:e5:7b", "SerialNumber": "removed", "Device": { "PCycleActual": 0, "ErrorMessages": "", "DeviceType": 1, "FTCVersion": 2600, "FTCRevision": "r0", "LastFTCVersion": 0, "LastFTCRevision": null, "FTCModel": 127, "RefridgerentAddress": 0, "SystemMaxFlowTemp": 0, "RefrigerantType": 0, "DipSwitch1": 0, "DipSwitch2": 0, "DipSwitch3": 0, "DipSwitch4": 0, "DipSwitch5": 0, "DipSwitch6": 0, "HasThermostatZone1": true, "HasThermostatZone2": true, "TemperatureIncrement": 0.5, "DefrostMode": 0, "HeatPumpFrequency": 0, "MaxSetTemperature": 50, "MinSetTemperature": 40, "RoomTemperatureZone1": 24, "RoomTemperatureZone2": -39, "OutdoorTemperature": 22, "FlowTemperature": 31, "FlowTemperatureZone1": 0, "FlowTemperatureZone2": 0, "FlowTemperatureBoiler": 0, "ReturnTemperature": 27, "ReturnTemperatureZone1": 0, "ReturnTemperatureZone2": 0, "ReturnTemperatureBoiler": 0, "BoilerStatus": false, "BoosterHeater1Status": false, "BoosterHeater2Status": false, "BoosterHeater2PlusStatus": false, "ImmersionHeaterStatus": false, "WaterPump1Status": false, "WaterPump2Status": false, "WaterPump3Status": false, "ValveStatus3Way": false, "ValveStatus2Way": false, "WaterPump4Status": false, "ValveStatus2Way2a": false, "ValveStatus2Way2b": false, "TankWaterTemperature": 60, "UnitStatus": 0, "HeatingFunctionEnabled": true, "ServerTimerEnabled": null, "ThermostatStatusZone1": false, "ThermostatStatusZone2": false, "ThermostatTypeZone1": 1, "ThermostatTypeZone2": 2, "MixingTankWaterTemperature": 0, "CondensingTemperature": 0, "DemandPercentage": 100, "ConfiguredDemandPercentage": null, "HasDemandSideControl": false, "DailyHeatingEnergyConsumed": 0.04, "DailyCoolingEnergyConsumed": 0, "DailyHotWaterEnergyConsumed": 2.01, "DailyHeatingEnergyProduced": 0.67, "DailyCoolingEnergyProduced": 0, "DailyHotWaterEnergyProduced": 4.95, "DailyLegionellaActivationCounter": 0, "LastLegionellaActivationTime": "0001-01-01T00:00:00", "EffectiveFlags": 0, "LastEffectiveFlags": 0, "Power": false, "EcoHotWater": false, "OperationMode": 0, "OperationModeZone1": 0, "OperationModeZone2": 2, "SetTemperatureZone1": 19, "SetTemperatureZone2": 20, "SetTankWaterTemperature": 70, "TargetHCTemperatureZone1": 19, "TargetHCTemperatureZone2": 35, "ForcedHotWaterMode": false, "HolidayMode": false, "ProhibitHotWater": false, "ProhibitHeatingZone1": true, "ProhibitHeatingZone2": true, "ProhibitCoolingZone1": false, "ProhibitCoolingZone2": false, "ServerTimerDesired": false, "SecondaryZoneHeatCurve": false, "SetHeatFlowTemperatureZone1": 0, "SetHeatFlowTemperatureZone2": 0, "SetCoolFlowTemperatureZone1": 0, "SetCoolFlowTemperatureZone2": 0, "DECCReport": false, "CSVReport1min": false, "Zone2Master": false, "DailyEnergyConsumedDate": "2024-08-05T00:00:00", "DailyEnergyProducedDate": "2024-08-05T00:00:00", "CurrentEnergyConsumed": 0, "CurrentEnergyProduced": 0, "CurrentEnergyMode": null, "HeatingEnergyConsumedRate1": 0, "HeatingEnergyConsumedRate2": 0, "CoolingEnergyConsumedRate1": 0, "CoolingEnergyConsumedRate2": 0, "HotWaterEnergyConsumedRate1": 0, "HotWaterEnergyConsumedRate2": 0, "HeatingEnergyProducedRate1": 0, "HeatingEnergyProducedRate2": 0, "CoolingEnergyProducedRate1": 0, "CoolingEnergyProducedRate2": 0, "HotWaterEnergyProducedRate1": 0, "HotWaterEnergyProducedRate2": 0, "ErrorCode2Digit": 0, "SpSubDivisionsToWrite": 0, "SpSubDivisionsToRead": 0, "SpState": 0, "SpSubDivisionsWriteInProgress": 0, "SpSubDivisionsReadInProgress": 0, "InitialSettingsData": null, "InitialSettingsTimestamp": null, "SupportsHourlyEnergyReport": false, "HasZone2": false, "HasSimplifiedZone2": false, "CanHeat": true, "CanCool": false, "HasHotWaterTank": true, "CanSetTankTemperature": true, "CanSetEcoHotWater": false, "HasEnergyConsumedMeter": true, "HasEnergyProducedMeter": true, "CanMeasureEnergyProduced": false, "CanMeasureEnergyConsumed": false, "Zone1InRoomMode": true, "Zone2InRoomMode": false, "Zone1InHeatMode": true, "Zone2InHeatMode": true, "Zone1InCoolMode": false, "Zone2InCoolMode": false, "AllowDualRoomTemperature": false, "IsGeodan": false, "HasEcoCuteSettings": true, "HasFTC45Settings": false, "HasFTC6Settings": false, "CanEstimateEnergyUsage": true, "CanUseRoomTemperatureCooling": false, "IsFtcModelSupported": true, "SystemMaxFlowTemperature": null, "MaxTankTemperature": 70, "IdleZone1": true, "IdleZone2": false, "MinPcycle": 1, "MaxPcycle": 1, "MaxOutdoorUnits": 255, "MaxIndoorUnits": 255, "MaxTemperatureControlUnits": 0, "ModelCode": "027a", "DeviceID": 116257407, "MacAddress": "8c:53:e6:30:e5:7b", "SerialNumber": "2422611007", "TimeZoneID": 119, "DiagnosticMode": 0, "DiagnosticEndDate": null, "ExpectedCommand": 1, "Owner": 1048479, "DetectedCountry": null, "AdaptorType": 3, "FirmwareDeployment": null, "FirmwareUpdateAborted": false, "LinkedDevice": null, "WifiSignalStrength": -54, "WifiAdapterStatus": "NORMAL", "Position": "Unknown", "PCycle": 2, "PCycleConfigured": null, "RecordNumMax": 1, "LastTimeStamp": "2024-08-06T16:04:00", "ErrorCode": 8000, "HasError": false, "LastReset": "2024-08-06T10:30:43.842", "FlashWrites": 1, "Scene": null, "TemperatureIncrementOverride": 0, "SSLExpirationDate": "2037-12-31T00:00:00", "SPTimeout": 1, "Passcode": null, "ServerCommunicationDisabled": false, "ConsecutiveUploadErrors": 0, "DoNotRespondAfter": null, "OwnerRoleAccessLevel": 1, "OwnerCountry": 217, "HideEnergyReport": false, "ExceptionHash": null, "ExceptionDate": null, "ExceptionCount": null, "Rate1StartTime": null, "Rate2StartTime": null, "ProtocolVersion": 0, "UnitVersion": 0, "FirmwareAppVersion": 37000, "FirmwareWebVersion": 0, "FirmwareWlanVersion": 0, "LinkToMELCloudHome": false, "LinkedByUserFromMELCloudHome": "00000000-0000-0000-0000-000000000000", "EffectivePCycle": 1, "MqttFlags": 9, "HasErrorMessages": false, "Offline": false, "Units": [ { "ID": 1, "Device": 0, "SerialNumber": "removed", "ModelNumber": 555, "Model": "QUHZ-W40VA", "UnitType": 0, "IsIndoor": false }, { "ID": 2, "Device": 0, "SerialNumber": "removed", "ModelNumber": 554, "Model": "EHPT20Q-VM2EA", "UnitType": 1, "IsIndoor": true } ] }, "DiagnosticMode": 0, "DiagnosticEndDate": null, "Location": 23968, "DetectedCountry": null, "Registrations": 6, "LocalIPAddress": null, "TimeZone": 119, "RegistReason": "CONFIG", "ExpectedCommand": 1, "RegistRetry": 0, "DateCreated": "2024-08-06T10:30:23.715Z", "FirmwareDeployment": null, "FirmwareUpdateAborted": false, "Permissions": { "CanSetForcedHotWater": true, "CanSetOperationMode": true, "CanSetPower": true, "CanSetTankWaterTemperature": true, "CanSetEcoHotWater": false, "CanSetFlowTemperature": true, "CanSetTemperatureIncrementOverride": true } }

grzegorz914 commented 3 months ago

fixed in 1.1.3, your tank can be set to 70 degrees, "MaxTankTemperature": 70,