Introduction

A reusable, barebones tools for streaming EMG samples directly from the Myo Armband through the armband's Bluetooth Smart interface (aka Bluetooth Low Energy) for Processing, bypassing the need to use the MyoConnect software.

This tool assumes that you are using the dongle provided with the myo armband, which communicates with the armband using Bluetooth LE, but presents itself to your computer as a serial communication device. This tool does therefore not work as-is with with a generic Bluetooth device or dongle.

The project is extremely barebones, and is currently not appropriate to be used as a generic Bluetooth LE interface or library. I've only implemented the Bluetooth LE functionality that was required for my specific use-case. Similarly, this is not a generic library for interfacing the Myo armband.

Background

The biggest hurdle in completing this project was learning how the Bluetooth communication occurred between the host computer and the armband. Trying to piece together the structure of the commands and responses was difficult because the information required to do so was scattered across many different sites, books, and projects. I'm including this background section to (hopefully) make the learning curve slightly less steep for those looking to do similar projects in the future.

Bluetooth Low Energy (BLE)

Bluetooth Low Energy (also called Bluetooth LE, BLE, or Bluetooth Smart) is a protocol specification that was first defined in the Bluetooth v4.0 spec. Bluetooth LE is not simply a sub-set of Bluetooth, but is instead a totally separate protocol designed from the ground up with low power consumption in mind. A great introduction to Bluetooth LE can be found in the first 4 chapters of O'Reilly Getting Started with Bluetooth Low Energy. Pay specific attention to chapter 4, the GATT protocol, as this covers the majority of interactions that will be conducted with a device through BLE.

Generic Attribute (GATT) protocol

Once a connection with a peripheral device is established (through a protocol known as GAP, discussed in chapter 3 of the book mentioned above), the client (i.e., computer, cell-phone) and server (i.e., armband, heart-rate monitor) communicate using a protocol known as GATT. Conceptually, the server is essentially a database which can be queried for data (which is known as an attribute) using either a UUID or a handle.

In the most basic use-case, the client queries the server using either a UUID or a handle, and subsequently receives a response containing the data of interest. However, the server can also be configured to push certain pieces of data asynchronously to the client through mechanism called notifications and indications

Characteristics, Attributes, Values and Descriptors

Aspect of GATT that I found confusing at first were the (seemingly) ambiguous use of the terms 'characteristic' and 'attribute', and the structure and indirection found in the GATT table.

Details of the GATT protocol

OReilly's Getting Started With Bluetooth Low Energy provided a great conceptual understanding of how the GATT protocol works, however, I had difficulty finding documentation for the structure and opcodes of the specific GATT commands. The bglib project provides a great overview of this information:

https://github.com/jrowberg/bglib

In general, all GATT messages start with a 4-byte header and are structured as follows:

'''

... ''' - **type**: For Bluetooth, either 0x00 (indicating that this is a command), or 0x80 (indicating that this is an asynchronous event, such as a notification) - **payloadSize**: The length of the payload. The entire message will be (4 + payloadSize) bytes. - **opcodeClass** / **opcodeCommand**: These two bytes specify which GATT command should be issued. For more details, see the `bglib` project. Many of the GATT commands use the first few bytes of the payload to hold additional information, such as the connection ID and the handle/UUID to read or write. ### Myo armband-specific protocol Commands for controlling the behavior of the armband are encoded in the payload of GATT-write commands, and a written to a specific attribute of the GATT table. To send a command to the Myo armband, use the 'write attribute by handle' GATT command to write a message to the 0x0019 handle. The payload of this message should contain the Myo-specific command. The structure and opcodes for Myo-specific commands can be found in the publicly available header-file, found here: https://github.com/thalmiclabs/myo-bluetooth/blob/master/myohw.h #### Myo EMG Here are links to a few articles that clearly explain the steps required to stream EMG data from the Myo armband: http://developerblog.myo.com/myo-bluetooth-spec-released/ http://developerblog.myo.com/myocraft-emg-in-the-bluetooth-protocol/ # Debugging Tools During this project, I learned to use a few Linux command line debugging tools that turned out to be incredibly useful for prototyping commands and visualizing the GATT table. - **hcitool**: This tool can be used to find the MAC address of a nearby BLE device. Issue the command: `hcitool -i hciX lescan`, replacing the X with the appropriate Bluetooth interface number. - **gatttool**: This tool can be used to connect with a BLE device in an interactive session. Within this session, you can issue commands and query the GATT table. Issue the command: `gatttool -b -I` to start an interactive session. # Reference Material Books: - OReilly Getting Started with Bluetooth Low Energy git projects: - bglib: https://github.com/jrowberg/bglib - myo-raw: https://github.com/dzhu/myo-raw Myo-specific information: - Blog Posts - http://developerblog.myo.com/myo-bluetooth-spec-released/ - http://developerblog.myo.com/myocraft-emg-in-the-bluetooth-protocol/ - Technical Specifications - https://github.com/thalmiclabs/myo-bluetooth/blob/master/myohw.h