maarten-pennings / CCS811

Arduino library for the CCS811 gas sensor for monitoring indoor air quality.
MIT License
165 stars 46 forks source link

Seek help from CCS811 #54

Closed wangmings closed 3 years ago

wangmings commented 3 years ago

setup: Starting CCS811 basic demo setup: ccs811 lib version: 10 setup: hardware version: 12 setup: bootloader version: 1000 setup: application version: 2000

Who knows if it's firmware or software

Problem specification

When errstat: 2201! It is difficult to wake up THE CCS811, when the measurement results are incorrect

errstat: 2201 CCS811_ERRSTAT_OK: 152 CCS811: eco2=400 ppm etvoc=0 ppb CCS811: errstat=899=--vhXmrwF--AD-iE errstat: 2201 CCS811_ERRSTAT_OK: 152 CCS811: eco2=400 ppm etvoc=0 ppb CCS811: errstat=899=--vhXmrwF--AD-iE errstat: 2201 CCS811_ERRSTAT_OK: 152

Normal execution:

errstat: 152
CCS811_ERRSTAT_OK: 152
CCS811: eco2=462 ppm  etvoc=9 ppb  CCS811: eco2=462 ppm  etvoc=9 ppb  
errstat: 152
CCS811_ERRSTAT_OK: 152
CCS811: eco2=454 ppm  etvoc=8 ppb  CCS811: eco2=454 ppm  etvoc=8 ppb  
errstat: 152
CCS811_ERRSTAT_OK: 152

CCS811 firmware 1.0.0 is also a problem with the above

setup: Starting CCS811 basic demo setup: ccs811 lib version: 10 setup: hardware version: 12 setup: bootloader version: 1000 setup: application version: 1000 errstat: 144 CCS811_ERRSTAT_OK: 152 CCS811: eco2=4096 ppm etvoc=0 ppb CCS811: waiting for (new) data errstat: 144 CCS811_ERRSTAT_OK: 152 CCS811: eco2=24713 ppm etvoc=65087 ppb CCS811: waiting for (new) data errstat: 152 CCS811_ERRSTAT_OK: 152 CCS811: eco2=0 ppm etvoc=0 ppb CCS811: eco2=0 ppm etvoc=0 ppb
errstat: 152 CCS811_ERRSTAT_OK: 152 CCS811: eco2=0 ppm etvoc=0 ppb CCS811: eco2=0 ppm etvoc=0 ppb
errstat: 153 CCS811_ERRSTAT_OK: 152 CCS811: eco2=24713 ppm etvoc=65087 ppb CCS811: errstat=99=--vhxmrwF--AD-iE errstat: 153 CCS811_ERRSTAT_OK: 152 CCS811: eco2=24713 ppm etvoc=65087 ppb CCS811: errstat=99=--vhxmrwF--AD-iE errstat: 153 CCS811_ERRSTAT_OK: 152 CCS811: eco2=24713 ppm etvoc=65087 ppb CCS811: errstat=99=--vhxmrwF--AD-iE errstat: 153 CCS811_ERRSTAT_OK: 152 CCS811: eco2=24713 ppm etvoc=65087 ppb CCS811: errstat=99=--vhxmrwF--AD-iE errstat: 153 CCS811_ERRSTAT_OK: 152 CCS811: eco2=24713 ppm etvoc=65087 ppb CCS811: errstat=99=--vhxmrwF--AD-iE errstat: 153 CCS811_ERRSTAT_OK: 152 CCS811: eco2=24713 ppm etvoc=65087 ppb CCS811: errstat=99=--vhxmrwF--AD-iE errstat: 153 CCS811_ERRSTAT_OK: 152 CCS811: eco2=24713 ppm etvoc=65087 ppb CCS811: errstat=99=--vhxmrwF--AD-iE