storcli_check.py
is a Python 2.4-compatible script that will check your
MegaRAID adapter for issues and send a report by email. It's designed to be
self contained and easily added to a cron job. The only file you need from this
repo is src/storcli_check.py
.
The following command-line parameters are optional:
--mailto
: Comma-separated list of emails to send the report to (e.g. "first1.last1@example.com,first2.other2@example.com"
)--mailserver
: The hostname of the SMTP server to use (e.g. "mailhost.example.com")--force
: Force the script to send the report even if everything's fine (useful for weekly status)--mailfrom
: The user the email will seem to come from. The default is <username>@<hostname>
.--mailcc
: Comma-separated list of emails to CC the report to (e.g. "first1.last1@example.com,first2.other2@example.com"
)--ignore
: Comma-separated list of controller IDs to ignore (e.g. 1,2
)
NOTE: If --mailto
and --mailserver
are ommited, the HTML report will be
printed on stdout according to the use of --force
.
Newer versions of storcli
show both HBA
and MR
controllers. The script
attempts to ignore all HBA
controllers reported by storcli
. This is done
by scraping the name of the driver being used by the controller.
See SUPPORTED_DRIVERS
in the configuration setting of the script if you need
to change it.
The script is a relatively simple parser and reporter for the storcli /cx show all
command. It checks to ensure that the controller's status is "optimal", all
virtual drives are "optimal", and all physical drives are "online", "unconfigured
good", "dedicated hot spare", or "global hot spare".
The report that is emailed contains some controller information, the list of
VDs, and the list of PDs. Any errors found during parsing are also reported.
You will also find a zip file the contains the output from show all
, show events
,
and also the MegaSAS.log
file that storcli
generates (one info and event file
for each controller).
I'm using this script to check the state of my LSI controller on a XenServer hypervisor. It was a lot easier than trying to figure out how to pass the controller to a guest VM and using MegaRAID Storage Manager, get MSM snmp installed and running on the hypervisor, etc. The requirements for this script are pretty minimal (in my opinion), and it is working in my lab.
I have it periodically running via cron
. It's working so far! I run the defaults
every 10 minutes (doesn't send logs if everything's ok), and --force
the report
once per week:
*/10 * * * * root /usr/local/bin/storcli-check --to=me@example.com --mailserver=mailhost.example.com 2>/dev/null
0 8 * * mon root /usr/local/bin/storcli-check --to=me@example.com --mailserver=mailhost.example.com --force 2>/dev/null
sendmail()
.If you find that the defaults don't work for you, you should be able to make modifications in the Configuration section of the source. I don't use any type of config file. The section is near the top of the script.
You may also need to play around with where to put storcli64
so this script
will find it. The script tries some obvious places (include cwd
), and each
path in $PATH
. If you have issues, an easy fix is to put the binary inside
/usr/local/bin
, since I always check that.
An attempt is made to report possible event problems. The following command is run for each controller:
/cx show events filter=warning,critical,fatal
If this command returns anything, the script will consider the controller to be in an error state. The script never clears the events. This means that you may get spammed depending on how often you: a) run the script; b) how quickly you address the issue; c) how soon you clear the events.
Here's an example of a sequence of events that will be reported by this script:
seqNum: 0x0000cf1a
Time: Tue Jun 2 18:02:08 2015
Code: 0x000000fb
Class: 2
Locale: 0x01
Event Description: VD 00/0 is now DEGRADED
Event Data:
===========
Target Id: 0
seqNum: 0x0000cf1d
Time: Tue Jun 2 18:03:11 2015
Code: 0x000000fc
Class: 3
Locale: 0x01
Event Description: VD 00/0 is now OFFLINE
Event Data:
===========
Target Id: 0
seqNum: 0x0000cf20
Time: Tue Jun 2 18:03:35 2015
Code: 0x000000fb
Class: 2
Locale: 0x01
Event Description: VD 00/0 is now DEGRADED
Event Data:
===========
Target Id: 0
In this mock-scenario, we had two drives go offline, which brought the VD
offline. We then replaced one of the drives, which moved the VD back into the
DEGRADED
state. Then we replaced the second drive, which moved the VD back
into the OPTIMAL
state. Notice, however, the OPTIMAL
event was not captured.
It doesn't show up since that event is not warning or above.
It's not a perfect system, but it serves its purpose. You'll need to clear the event log of the offending controller to get the report to stop spamming your email.