HDL Coder™ Support Package for NI FPGA Hardware enables generating bitfiles for NI FPGA hardware from HDL Coder by providing LabVIEW FPGA integration.
This workflow allows you to perform the following actions:
Note: This support package is functional for R2022b and later releases listed in the table below
For 32-bit LabVIEW - | HDL Coder™ Support Package for NI FPGA Hardware | MathWorks Simulink® | LabVIEW Full or Professional Development Systems(32-bit) | LabVIEW FPGA Module(32-bit) | NI R Series Multifunction RIO with LabVIEW Support(32-bit)** | FlexRIO with Integrated IO(PXIe-7890/7891)*** | IP to FPGA Conversion Utility |
---|---|---|---|---|---|---|---|
24.5 (2024 Q3) | R2024a R2023b R2023a R2022b |
2021 | 2021 | 2024 Q3 | 2024 Q3 | 2024 Q3 | |
24.0 (2024 Q1) | R2023b R2023a R2022b* |
2020 and 2021 | 2020 and 2021 | 2023 Q2 | 2023 Q2(Only LabVIEW 2021 supported) | 2024 Q1 | |
23.5 (2023 Q3) | R2023a R2022b |
2020 and 2021 | 2020 and 2021 | 2023 Q2 | 2023 Q2(Only LabVIEW 2021 supported) | 2023 Q3 | |
23.3 (2023 Q2) | R2023a R2022b |
2020 and 2021 | 2020 and 2021 | 2023 Q1 | Not Supported | 2023 Q2 | |
23.0 (2023 Q1) | R2022b* | 2019, 2020 and 2021 | 2019, 2020 and 2021 | 2022 Q4 | Not Supported | 2023 Q1 |
For 64-bit LabVIEW - | HDL Coder™ Support Package for NI FPGA Hardware | MathWorks Simulink® | LabVIEW Full or Professional Development Systems(64-bit) | LabVIEW FPGA Module(64-bit) | NI R Series Multifunction RIO with LabVIEW Support(64-bit)** | FlexRIO with Integrated IO(PXIe-7890/7891)*** | IP to FPGA Conversion Utility |
---|---|---|---|---|---|---|---|
24.5 (2024 Q3) | R2024a R2023b R2023a R2022b |
2023 and 2024 | 2023 and 2024 | 2024 Q3 | 2024 Q3 | 2024 Q3 | |
24.0 (2024 Q1) | R2023b R2023a R2022b* |
2023 | 2023 | 2023 Q2 | 2023 Q2 | 2024 Q1 | |
23.5 (2023 Q3) | R2023a R2022b |
2023 | 2023 | 2023 Q2 | 2023 Q2 | 2023 Q3 | |
23.3 (2023 Q2) | R2023a R2022b |
2023 | 2023 | 2023 Q1 | Not Supported | 2023 Q2 |
* make sure to look up the known issues table and apply any suggested workarounds accordingly before using release 24.5.
** Note: NI R Series Multifunction RIO with LabVIEW Support driver is required only for R-series devices.
* Note: FlexRIO with Integrated IO** driver is needed only for PXIe-7890/7891 devices.
Before you begin, install the supported versions of MathWorks MATLAB®, Simulink® and HDL Coder™.
Install and activate LabVIEW Full or Professional Development Systems , LabVIEW FPGA Module, NI R Series Multifunction RIO LabVIEW Support, FlexRIO and IP to FPGA Conversion Utility.