Important: Due to dedicated Tuya API limitation, the refresh interval cannot be faster than 5 minutes (reduced to 1 minute if you have only 1 device). Do not open issue to ask faster refresh because it is not possible.
This custom component is the copy of the component implemented in Home Assistant but some modifications to the library used to communicate with Tuya Cloud have been implemented inside it. The aim is to allow tests on the modified library as quickly as possible and then report the changes in the original library used by HA. Obviously, feedback is important to find an optimal solution
You can install this component in two ways: via HACS or manually.
If you have HACS, you must add this repository ("https://github.com/ollo69/ha_tuya_custom") to your Custom Repository selecting the Configuration Tab in the HACS page. After this you can go in the Integration Tab and search the "Tuya Custom" component to configure it.
Unzip/copy the tuya_custom direcotry within the custom_components
directory of your homeassistant installation.
The custom_components
directory resides within your homeassistant configuration directory.
Usually, the configuration directory is within your home (~/.homeassistant/
).
In other words, the configuration directory of homeassistant is where the configuration.yaml file is located.
After a correct installation, your configuration directory should look like the following.
└── ...
└── configuration.yaml
└── secrects.yaml
└── custom_components
└── tuya_custom
└── __init__.py
└── climate.py
└── ...
Note: if the custom_components directory does not exist, you need to create it.
For the configuration use exactly the same options used to configure the standard Tuya component, however choosing the Tuya Custom component from the list of additions.
N.B. Before configuring this integration, remove the standard Tuya integration.
It is possible to change various behaviors through the integration options, some common for integration and others specific to each light
and climate
devices. These can be changed at Tuya Custom -> Options on the Integrations page.
Discovery device polling interval (default=605): define the interval between 2 consecutive calls to the API discovery method
, which is used to get the status for all registered devices with a single call. If you set interval value too low, Tuya API will return errors, so it is suggested to use the default value until
you know that it is possible to use lower values.
Query device polling interval (default=120): this option is available only if you have devices that can use the API query method
.
It defines the interval between 2 consecutive calls to the API query method
, that is used to get the status for a specific device.
This method is always used when it is available only one device that can use it. If you set interval value too low, Tuya API will return errors
so it is suggested to use the default value until you know that is possible to use lower values.
Device that will use the query method: this option is available only if you have devices that can use the API query method
.
Because it is not possible to make multiple calls to the API query method
. If you have more than one device that can use it you can choose which one will use. This will give a better status refresh for this specific device.
Device to configure (multi-select list): this option is available only if you have a light
or climate
device. Selecting a device to
configure to options page related to the device will be opened. You can also select more than one devices to configure them simultaneously,
but all selected devices must be of the same type.
Force color support: when checked force color support
for devices that do not report this feature.
Brightness range: change the brightness range
used for the device. Possible options are:
Min color temperature: set minimum color temperature
expressed in kelvin
accepted by the light.
Max color temperature: set maximum color temperature
expressed in kelvin
accepted by the light.
Max color temperature reported: set the maximum color temperature
value reported by the light.
Temperature unit: change the temperature unit
used internally by the devices.
Temperature values divider: all temperatures
reported by device will be divided by this value.
Current Temperature value divider: current temperature
reported by device will be divided by this value.
Set Temperature value divided: when checked use the divided temperature value for set temperature
command.
Target Temperature step: set the temperature step used to set target temperature.
Min target temperature: set the minimum allowed target temperature
for the entity.
Max target temperature: set the maximum allowed target temperature
for the entity.
Sensor for current temperature: any HA sensor entity that provide current temperature
, used when not available from device.
Configuration of device parameter using configuration.yaml
is not supported anymore. Use integration options for this.
Please note that option previously set in configuration file will not be loaded anymore and must be configured again from integration page.