Open AKB-OU opened 1 year ago
Dear all,
Happy new year.
I have not been able to solve the problem yet. The absolute values of the conductivity depend on the used version.
I attach a comparison of the result obtained by v2.5.1 and latest versions. LAS_comp.pdf
By the way, the above phenomena can be seen in Cu tutorial as attached below. Cu_theta0_comp.pdf
Best, AKB
Looks like a factor of two is there between the versions. I was able to reproduce the results of Cu between v2.7.0 and v2.5.1. The plot matches after x2 for the results calculated by v2.7.0.
Dear Dongsheng-Wen,
Thank you for the information. In my opinion, this problem has remained unsettled in the versions >= 2.6.
Best, AKB
Dear developers and users,
Hi.
In the latest release version 2.6.2, I encountered a problem in the OHE calculation that sigma_xx (and thus rho_xx) become negative at high B*tau values. This problem does not arise in the version 2.5.1, which is tested with exactly the same inputs.
I noticed that the lattice information seems to be wrongly recognized in 2.6.2: In 2.5.1, my tetragonal system is properly recognized like
But in 2.6.2, the angles alpha, beta, and gamma are strange like
In addition, "Atom position and magnetic moment of Original lattice" in WT.out depends on the used version.
I attached my TB hamiltonian and wt.in for your reference. hr_and_input.zip
Best regards, AKB-OU