[Question] Enphase IQ Batteries not showing up #116

Closed keesvanbemmel closed 2 months ago

keesvanbemmel commented 2 months ago

Hi!

Has anyone been able to have this integration pick up Enphase home batteries? And then also added them to the Energy dashboard?

Currently the integration doesn't show the newly installed batteries, even after removing, readding and reauthenticating the integration.

Thanks for any pointers!

vincentwolsink commented 2 months ago

Hi @keesvanbemmel, I don’t have batteries myself. Can you share your diagnostics file? I will take a look.

keesvanbemmel commented 2 months ago

I would love to! Where can I find those? :)

vincentwolsink commented 2 months ago

Open your Home Assistant instance and show an integration.

Click the three dots next to your Envoy on the right and click Download Diagnostics.

keesvanbemmel commented 2 months ago

Is there a way I can DM it to you?

vincentwolsink commented 2 months ago

You can send it to this temporary e-mail: ziener06joduur@icloud.com

keesvanbemmel commented 2 months ago

done!

vincentwolsink commented 2 months ago

Can you maybe send me the output of https://YOUR_ENVOY_IP/ivp/ensemble/inventory (after logging in to the Envoy). If you don't know the IP of your Envoy you can go to the Envoy device in Home Assistant and press the 'Visit' button.

keesvanbemmel commented 2 months ago
[
    {
        "type": "ENCHARGE",
        "devices": [
            {
                "part_num": "830-01760-r46",
                "installed": 1712942814,
                "serial_num": "122323085065",
                "device_status": [
                    "envoy.global.ok",
                    "prop.done"
                ],
                "last_rpt_date": 1712944638,
                "admin_state": 6,
                "admin_state_str": "ENCHG_STATE_READY",
                "created_date": 1712942814,
                "img_load_date": 1712942814,
                "img_pnum_running": "2.6.5973_rel/22.11",
                "zigbee_dongle_fw_version": "100F",
                "bmu_fw_version": "2.1.34",
                "operating": true,
                "communicating": true,
                "sleep_enabled": false,
                "percentFull": 20,
                "temperature": 20,
                "maxCellTemp": 20,
                "comm_level_sub_ghz": 4,
                "comm_level_2_4_ghz": 4,
                "led_status": 17,
                "dc_switch_off": false,
                "encharge_rev": 2,
                "encharge_capacity": 3500
            },
            {
                "part_num": "830-01760-r46",
                "installed": 1712942814,
                "serial_num": "122323085067",
                "device_status": [
                    "envoy.global.ok",
                    "prop.done"
                ],
                "last_rpt_date": 1712944677,
                "admin_state": 6,
                "admin_state_str": "ENCHG_STATE_READY",
                "created_date": 1712942814,
                "img_load_date": 1712942814,
                "img_pnum_running": "2.6.5973_rel/22.11",
                "zigbee_dongle_fw_version": "100F",
                "bmu_fw_version": "2.1.34",
                "operating": true,
                "communicating": true,
                "sleep_enabled": false,
                "percentFull": 20,
                "temperature": 20,
                "maxCellTemp": 20,
                "comm_level_sub_ghz": 4,
                "comm_level_2_4_ghz": 4,
                "led_status": 17,
                "dc_switch_off": false,
                "encharge_rev": 2,
                "encharge_capacity": 3500
            },
            {
                "part_num": "830-01760-r46",
                "installed": 1712942449,
                "serial_num": "122323085069",
                "device_status": [
                    "envoy.global.ok",
                    "prop.done"
                ],
                "last_rpt_date": 1712944722,
                "admin_state": 6,
                "admin_state_str": "ENCHG_STATE_READY",
                "created_date": 1712942449,
                "img_load_date": 1712942449,
                "img_pnum_running": "2.6.5973_rel/22.11",
                "zigbee_dongle_fw_version": "100F",
                "bmu_fw_version": "2.1.34",
                "operating": true,
                "communicating": true,
                "sleep_enabled": false,
                "percentFull": 20,
                "temperature": 20,
                "maxCellTemp": 20,
                "comm_level_sub_ghz": 4,
                "comm_level_2_4_ghz": 4,
                "led_status": 17,
                "dc_switch_off": false,
                "encharge_rev": 2,
                "encharge_capacity": 3500
            }
        ]
    }
]
vincentwolsink commented 2 months ago

I am working on a new implementation for the batteries. Will release a new beta soon.

keesvanbemmel commented 2 months ago

Would be great if we could also set the import export tariff from the integration Screenshot_20240414-133053

vincentwolsink commented 2 months ago

First step to better battery support: 0.3.7-beta1

keesvanbemmel commented 2 months ago

Batteries show up and also brings back all sensors (see #117 )

I'll test the upcoming days!

keesvanbemmel commented 2 months ago

@vincentwolsink if you look at the raw data, is there a metric that shows how much energy is flowing to/from the batteries? Seems like I can only get the current capacity, but the energy dashboards requires energy flows

vincentwolsink commented 2 months ago

I did not find it yet. I will take a closer look at the data later. Good to hear things are working for you now at least.

keesvanbemmel commented 2 months ago

Thanks for such a quick turnaround!

vincentwolsink commented 2 months ago

@keesvanbemmel Could you provide me your output for https://YOUR_ENVOY_IP/production.json?details=1

keesvanbemmel commented 2 months ago

Sure thing, here you go. It doesn't really show anything battery related though. Only the two production phases (I have only 2, not 3) and the 3 consumption phases. The storage seems idle even though the live status says it is discharging (with 0.1kW).

{
  "production": [
    {
      "type": "inverters",
      "activeCount": 28,
      "readingTime": 1713200109,
      "wNow": 2731,
      "whLifetime": 950214
    },
    {
      "type": "eim",
      "activeCount": 1,
      "measurementType": "production",
      "readingTime": 1713200138,
      "wNow": 502.888,
      "whLifetime": 191377.398,
      "varhLeadLifetime": 156.765,
      "varhLagLifetime": 109145.762,
      "vahLifetime": 255687.981,
      "rmsCurrent": 2.909,
      "rmsVoltage": 467.682,
      "reactPwr": 436.628,
      "apprntPwr": 678.833,
      "pwrFactor": 0.74,
      "whToday": 17354,
      "whLastSevenDays": 122780,
      "vahToday": 21023,
      "varhLeadToday": 0.765,
      "varhLagToday": 7542,
      "lines": [
        {
          "wNow": 254.284,
          "whLifetime": 95440.931,
          "varhLeadLifetime": 156.485,
          "varhLagLifetime": 55733.957,
          "vahLifetime": 128439.569,
          "rmsCurrent": 1.481,
          "rmsVoltage": 234.098,
          "reactPwr": 217.758,
          "apprntPwr": 345.267,
          "pwrFactor": 0.73,
          "whToday": 8820.931,
          "whLastSevenDays": 61281.931,
          "vahToday": 10627.569,
          "varhLeadToday": 0.485,
          "varhLagToday": 3805.957
        },
        {
          "wNow": 248.604,
          "whLifetime": 95936.467,
          "varhLeadLifetime": 0.28,
          "varhLagLifetime": 53411.805,
          "vahLifetime": 127248.412,
          "rmsCurrent": 1.428,
          "rmsVoltage": 233.584,
          "reactPwr": 218.871,
          "apprntPwr": 333.566,
          "pwrFactor": 0.75,
          "whToday": 8942.467,
          "whLastSevenDays": 61907.467,
          "vahToday": 10816.412,
          "varhLeadToday": 0.28,
          "varhLagToday": 3814.805
        }
      ]
    }
  ],
  "consumption": [
    {
      "type": "eim",
      "activeCount": 1,
      "measurementType": "total-consumption",
      "readingTime": 1713200138,
      "wNow": 480.639,
      "whLifetime": 251478.293,
      "varhLeadLifetime": 263806.659,
      "varhLagLifetime": -106386.694,
      "vahLifetime": 528517.373,
      "rmsCurrent": 3.059,
      "rmsVoltage": 702.103,
      "reactPwr": -556.11,
      "apprntPwr": 716.448,
      "pwrFactor": 0.69,
      "whToday": 14570.293,
      "whLastSevenDays": 9455.293,
      "vahToday": 29856.373,
      "varhLeadToday": 19258.659,
      "varhLagToday": 267,
      "lines": [
        {
          "wNow": 289.424,
          "whLifetime": 122113.523,
          "varhLeadLifetime": 129175.695,
          "varhLagLifetime": -51900.288,
          "vahLifetime": 262992.471,
          "rmsCurrent": 3.74,
          "rmsVoltage": 234.103,
          "reactPwr": -263.289,
          "apprntPwr": 875.602,
          "pwrFactor": 0.33,
          "whToday": 3951.523,
          "whLastSevenDays": 55.523,
          "vahToday": 13101.471,
          "varhLeadToday": 8691.695,
          "varhLagToday": 0
        },
        {
          "wNow": 175.725,
          "whLifetime": 104105.19,
          "varhLeadLifetime": 130870.853,
          "varhLagLifetime": -52611.861,
          "vahLifetime": 233251.227,
          "rmsCurrent": -0.978,
          "rmsVoltage": 233.731,
          "reactPwr": -306.173,
          "apprntPwr": -228.503,
          "pwrFactor": 1,
          "whToday": 9064.19,
          "whLastSevenDays": 23.19,
          "vahToday": 14799.227,
          "varhLeadToday": 10526.853,
          "varhLagToday": 0
        },
        {
          "wNow": 15.49,
          "whLifetime": 25259.58,
          "varhLeadLifetime": 3760.111,
          "varhLagLifetime": -1874.545,
          "vahLifetime": 32273.675,
          "rmsCurrent": 0.296,
          "rmsVoltage": 234.269,
          "reactPwr": 13.352,
          "apprntPwr": 69.348,
          "pwrFactor": 0.22,
          "whToday": 1554.58,
          "whLastSevenDays": 9376.58,
          "vahToday": 1955.675,
          "varhLeadToday": 40.111,
          "varhLagToday": 267
        }
      ]
    },
    {
      "type": "eim",
      "activeCount": 1,
      "measurementType": "net-consumption",
      "readingTime": 1713200138,
      "wNow": -24.056,
      "whLifetime": 60693.869,
      "varhLeadLifetime": 263964.089,
      "varhLagLifetime": 5678.254,
      "vahLifetime": 528517.373,
      "rmsCurrent": 0.01,
      "rmsVoltage": 702.103,
      "reactPwr": -992.738,
      "apprntPwr": 3.306,
      "pwrFactor": -1,
      "whToday": 0,
      "whLastSevenDays": 0,
      "vahToday": 0,
      "varhLeadToday": 0,
      "varhLagToday": 0,
      "lines": [
        {
          "wNow": 35.14,
          "whLifetime": 27272.029,
          "varhLeadLifetime": 129332.179,
          "varhLagLifetime": 3833.669,
          "vahLifetime": 262992.471,
          "rmsCurrent": 2.26,
          "rmsVoltage": 234.103,
          "reactPwr": -481.046,
          "apprntPwr": 528.968,
          "pwrFactor": 0.07,
          "whToday": 0,
          "whLastSevenDays": 0,
          "vahToday": 0,
          "varhLeadToday": 0,
          "varhLagToday": 0
        },
        {
          "wNow": -72.879,
          "whLifetime": 8716.425,
          "varhLeadLifetime": 130871.134,
          "varhLagLifetime": 799.944,
          "vahLifetime": 233251.227,
          "rmsCurrent": -2.406,
          "rmsVoltage": 233.731,
          "reactPwr": -525.044,
          "apprntPwr": -562.279,
          "pwrFactor": -1,
          "whToday": 0,
          "whLastSevenDays": 0,
          "vahToday": 0,
          "varhLeadToday": 0,
          "varhLagToday": 0
        },
        {
          "wNow": 13.683,
          "whLifetime": 24705.415,
          "varhLeadLifetime": 3760.776,
          "varhLagLifetime": 1044.641,
          "vahLifetime": 32273.675,
          "rmsCurrent": 0.156,
          "rmsVoltage": 234.269,
          "reactPwr": 13.352,
          "apprntPwr": 36.618,
          "pwrFactor": 0.37,
          "whToday": 0,
          "whLastSevenDays": 0,
          "vahToday": 0,
          "varhLeadToday": 0,
          "varhLagToday": 0
        }
      ]
    }
  ],
  "storage": [
    {
      "type": "acb",
      "activeCount": 0,
      "readingTime": 0,
      "wNow": 0,
      "whNow": 0,
      "state": "idle"
    }
  ]
}
vincentwolsink commented 2 months ago

Could you please also provide the output for the following urls (sorry for asking but I don't have batteries myself).

https://YOUR_ENVOY_IP/ivp/ensemble/power https://YOUR_ENVOY_IP/ivp/ensemble/secctrl https://YOUR_ENVOY_IP/ivp/ensemble/status https://YOUR_ENVOY_IP/ivp/ensemble/relay

keesvanbemmel commented 2 months ago

More than happy to help!

power:

{
    "devices:": [
        {
            "serial_num": "122323085065",
            "real_power_mw": 179000,
            "apparent_power_mva": 179000,
            "soc": 89
        },
        {
            "serial_num": "122323085067",
            "real_power_mw": 190000,
            "apparent_power_mva": 190000,
            "soc": 89
        },
        {
            "serial_num": "122323085069",
            "real_power_mw": 183000,
            "apparent_power_mva": 183000,
            "soc": 89
        }
    ]
}

secctrl:

{
    "shutdown": false,
    "freq_bias_hz": 0.19460000097751618,
    "voltage_bias_v": 2.365999937057495,
    "freq_bias_hz_q8": 313,
    "voltage_bias_v_q5": 75,
    "freq_bias_hz_phaseb": 0.0,
    "voltage_bias_v_phaseb": 0.0,
    "freq_bias_hz_q8_phaseb": 0,
    "voltage_bias_v_q5_phaseb": 0,
    "freq_bias_hz_phasec": 0.0,
    "voltage_bias_v_phasec": 0.0,
    "freq_bias_hz_q8_phasec": 0,
    "voltage_bias_v_q5_phasec": 0,
    "configured_backup_soc": 0,
    "adjusted_backup_soc": 0,
    "agg_soc": 89,
    "Max_energy": 10500,
    "ENC_agg_soc": 89,
    "ENC_agg_soh": 100,
    "ENC_agg_backup_energy": 0,
    "ENC_agg_avail_energy": 9345,
    "Enc_commissioned_capacity": 10500,
    "Enc_max_available_capacity": 10500,
    "ACB_agg_soc": 0,
    "ACB_agg_energy": 0
}

relay:

{
    "mains_admin_state": "closed",
    "mains_oper_state": "closed",
    "der1_state": 0,
    "der2_state": 0,
    "Enchg_grid_mode": "grid-tied",
    "Solar_grid_mode": "unknown"
}

status:

{
    "inventory": {
        "serial_nums": {
            "122323085065": {
                "device_type": 13,
                "admin_state": 6,
                "admin_state_str": "ENCHG_STATE_READY",
                "reported_grid_mode": "grid-tied",
                "phase": 1,
                "encharge_revision": 2,
                "encharge_capacity": 3500,
                "encharge_rated_power": 1280,
                "msg_retry_count": 0,
                "part_number": "830-01760-r46",
                "assembly_number": "890-00023-r48",
                "app_fw_version": "2.6.5973_rel/22.11",
                "zb_fw_version": "100F",
                "zb_bootloader_vers": "1.B.5",
                "ibl_fw_version": "1.3.413",
                "swift_asic_fw_version": "001.002.1.7.2",
                "bmu_fw_version": "2.1.34",
                "submodule_count": 6,
                "submodules": {
                    "122321067557": {
                        "device_type": 16,
                        "admin_state": 1,
                        "part_number": "620-00291-r02",
                        "assembly_number": "800-00291-r02",
                        "dmir": {
                            "part_number": "",
                            "assembly_number": ""
                        },
                        "procload": {
                            "part_number": "490-00154",
                            "assembly_number": "2.1.34"
                        }
                    },
                    "122322019637": {
                        "device_type": 15,
                        "admin_state": 1,
                        "part_number": "800-01854-r06",
                        "assembly_number": "800-01854-r06",
                        "dmir": {
                            "part_number": "546-00002-01",
                            "assembly_number": "01"
                        },
                        "procload": {
                            "part_number": "522-00002-01",
                            "assembly_number": "2.6.5973_rel/22.11"
                        }
                    },
                    "122322116871": {
                        "device_type": 14,
                        "admin_state": 1,
                        "part_number": "800-01335-r01",
                        "assembly_number": "880-01335-r14",
                        "dmir": {
                            "part_number": "549-00030-r00",
                            "assembly_number": "3.9.5-D15"
                        },
                        "procload": {
                            "part_number": "521-00003-r13",
                            "assembly_number": "3.9.1-D15"
                        }
                    },
                    "122322116905": {
                        "device_type": 14,
                        "admin_state": 1,
                        "part_number": "800-01335-r01",
                        "assembly_number": "880-01335-r14",
                        "dmir": {
                            "part_number": "549-00030-r00",
                            "assembly_number": "3.9.5-D15"
                        },
                        "procload": {
                            "part_number": "521-00003-r13",
                            "assembly_number": "3.9.1-D15"
                        }
                    },
                    "122322124448": {
                        "device_type": 14,
                        "admin_state": 1,
                        "part_number": "800-01335-r01",
                        "assembly_number": "880-01335-r14",
                        "dmir": {
                            "part_number": "549-00030-r00",
                            "assembly_number": "3.9.5-D15"
                        },
                        "procload": {
                            "part_number": "521-00003-r13",
                            "assembly_number": "3.9.1-D15"
                        }
                    },
                    "122322125098": {
                        "device_type": 14,
                        "admin_state": 1,
                        "part_number": "800-01335-r01",
                        "assembly_number": "880-01335-r14",
                        "dmir": {
                            "part_number": "549-00030-r00",
                            "assembly_number": "3.9.5-D15"
                        },
                        "procload": {
                            "part_number": "521-00003-r13",
                            "assembly_number": "3.9.1-D15"
                        }
                    }
                }
            },
            "122323085067": {
                "device_type": 13,
                "admin_state": 6,
                "admin_state_str": "ENCHG_STATE_READY",
                "reported_grid_mode": "grid-tied",
                "phase": 1,
                "encharge_revision": 2,
                "encharge_capacity": 3500,
                "encharge_rated_power": 1280,
                "msg_retry_count": 0,
                "part_number": "830-01760-r46",
                "assembly_number": "890-00023-r48",
                "app_fw_version": "2.6.5973_rel/22.11",
                "zb_fw_version": "100F",
                "zb_bootloader_vers": "1.B.5",
                "ibl_fw_version": "1.3.413",
                "swift_asic_fw_version": "001.002.1.7.2",
                "bmu_fw_version": "2.1.34",
                "submodule_count": 6,
                "submodules": {
                    "122322020028": {
                        "device_type": 15,
                        "admin_state": 1,
                        "part_number": "800-01854-r06",
                        "assembly_number": "800-01854-r06",
                        "dmir": {
                            "part_number": "546-00002-01",
                            "assembly_number": "01"
                        },
                        "procload": {
                            "part_number": "522-00002-01",
                            "assembly_number": "2.6.5973_rel/22.11"
                        }
                    },
                    "122322085064": {
                        "device_type": 16,
                        "admin_state": 1,
                        "part_number": "620-00291-r02",
                        "assembly_number": "800-00291-r02",
                        "dmir": {
                            "part_number": "",
                            "assembly_number": ""
                        },
                        "procload": {
                            "part_number": "490-00154",
                            "assembly_number": "2.1.34"
                        }
                    },
                    "122322116058": {
                        "device_type": 14,
                        "admin_state": 1,
                        "part_number": "800-01335-r01",
                        "assembly_number": "880-01335-r14",
                        "dmir": {
                            "part_number": "549-00030-r00",
                            "assembly_number": "3.9.5-D15"
                        },
                        "procload": {
                            "part_number": "521-00003-r13",
                            "assembly_number": "3.9.1-D15"
                        }
                    },
                    "122322124430": {
                        "device_type": 14,
                        "admin_state": 1,
                        "part_number": "800-01335-r01",
                        "assembly_number": "880-01335-r14",
                        "dmir": {
                            "part_number": "549-00030-r00",
                            "assembly_number": "3.9.5-D15"
                        },
                        "procload": {
                            "part_number": "521-00003-r13",
                            "assembly_number": "3.9.1-D15"
                        }
                    },
                    "122322124472": {
                        "device_type": 14,
                        "admin_state": 1,
                        "part_number": "800-01335-r01",
                        "assembly_number": "880-01335-r14",
                        "dmir": {
                            "part_number": "549-00030-r00",
                            "assembly_number": "3.9.5-D15"
                        },
                        "procload": {
                            "part_number": "521-00003-r13",
                            "assembly_number": "3.9.1-D15"
                        }
                    },
                    "122322125026": {
                        "device_type": 14,
                        "admin_state": 1,
                        "part_number": "800-01335-r01",
                        "assembly_number": "880-01335-r14",
                        "dmir": {
                            "part_number": "549-00030-r00",
                            "assembly_number": "3.9.5-D15"
                        },
                        "procload": {
                            "part_number": "521-00003-r13",
                            "assembly_number": "3.9.1-D15"
                        }
                    }
                }
            },
            "122323085069": {
                "device_type": 13,
                "admin_state": 6,
                "admin_state_str": "ENCHG_STATE_READY",
                "reported_grid_mode": "grid-tied",
                "phase": 1,
                "encharge_revision": 2,
                "encharge_capacity": 3500,
                "encharge_rated_power": 1280,
                "msg_retry_count": 1,
                "part_number": "830-01760-r46",
                "assembly_number": "890-00023-r48",
                "app_fw_version": "2.6.5973_rel/22.11",
                "zb_fw_version": "100F",
                "zb_bootloader_vers": "1.B.5",
                "ibl_fw_version": "1.3.413",
                "swift_asic_fw_version": "001.002.1.7.2",
                "bmu_fw_version": "2.1.34",
                "submodule_count": 6,
                "submodules": {
                    "122322020280": {
                        "device_type": 15,
                        "admin_state": 1,
                        "part_number": "800-01854-r06",
                        "assembly_number": "800-01854-r06",
                        "dmir": {
                            "part_number": "546-00002-01",
                            "assembly_number": "01"
                        },
                        "procload": {
                            "part_number": "522-00002-01",
                            "assembly_number": "2.6.5973_rel/22.11"
                        }
                    },
                    "122322085063": {
                        "device_type": 16,
                        "admin_state": 1,
                        "part_number": "620-00291-r02",
                        "assembly_number": "800-00291-r02",
                        "dmir": {
                            "part_number": "",
                            "assembly_number": ""
                        },
                        "procload": {
                            "part_number": "490-00154",
                            "assembly_number": "2.1.34"
                        }
                    },
                    "122322113637": {
                        "device_type": 14,
                        "admin_state": 1,
                        "part_number": "800-01335-r01",
                        "assembly_number": "880-01335-r14",
                        "dmir": {
                            "part_number": "549-00030-r00",
                            "assembly_number": "3.9.5-D15"
                        },
                        "procload": {
                            "part_number": "521-00003-r13",
                            "assembly_number": "3.9.1-D15"
                        }
                    },
                    "122322116843": {
                        "device_type": 14,
                        "admin_state": 1,
                        "part_number": "800-01335-r01",
                        "assembly_number": "880-01335-r14",
                        "dmir": {
                            "part_number": "549-00030-r00",
                            "assembly_number": "3.9.5-D15"
                        },
                        "procload": {
                            "part_number": "521-00003-r13",
                            "assembly_number": "3.9.1-D15"
                        }
                    },
                    "122322124210": {
                        "device_type": 14,
                        "admin_state": 1,
                        "part_number": "800-01335-r01",
                        "assembly_number": "880-01335-r14",
                        "dmir": {
                            "part_number": "549-00030-r00",
                            "assembly_number": "3.9.5-D15"
                        },
                        "procload": {
                            "part_number": "521-00003-r13",
                            "assembly_number": "3.9.1-D15"
                        }
                    },
                    "122322124455": {
                        "device_type": 14,
                        "admin_state": 1,
                        "part_number": "800-01335-r01",
                        "assembly_number": "880-01335-r14",
                        "dmir": {
                            "part_number": "549-00030-r00",
                            "assembly_number": "3.9.5-D15"
                        },
                        "procload": {
                            "part_number": "521-00003-r13",
                            "assembly_number": "3.9.1-D15"
                        }
                    }
                }
            }
        }
    },
    "counters": {
        "api_ecagtInit": 1,
        "api_ecagtTick": 623563,
        "api_ecagtDeviceInsert": 3,
        "api_ecagtDeviceNetworkStatus": 25697,
        "api_ecagtDeviceCommissionStatus": 18,
        "api_ecagtGetDeviceCount": 628795,
        "api_ecagtGetDeviceInfo": 628156,
        "api_ecagtGetOneDeviceInfo": 6,
        "api_ecagtDevIdToSerial": 36689,
        "api_ecagtHandleMsg": 36050,
        "api_ecagtGetSubmoduleInv": 4029,
        "api_ecagtGetDataModelRaw": 9792,
        "api_ecagtSetSecCtrlBias": 57851,
        "api_ecagtGetSecCtrlBias": 547,
        "api_ecagtGetSecCtrlBiasQ": 5,
        "api_ecagtGetRelayState": 748490,
        "api_ecagtSetDataModelCache": 1,
        "api_AggNameplate": 2,
        "api_ecagtGetGridFreq": 124712,
        "api_ecagtGetGridVolt": 124712,
        "api_ecagtGetGridFreq_err_notfound": 124712,
        "rest_StatusGet": 3,
        "rest_SleepGet": 1,
        "rest_InventoryGet": 2693,
        "rest_SubmodGet": 1127,
        "rest_SecCtrlGet": 3,
        "rest_CommCheckGet": 12,
        "rest_Power": 7,
        "ext_zb_send_msg": 62436,
        "ext_cfg_save_device": 3,
        "ext_cfg_save_device_err": 3,
        "ext_send_perf_data": 34561,
        "ext_event_set_stateful": 3237,
        "ext_event_set_modgone": 12,
        "rxmsg_OBJ_MDL_META_RSP": 3,
        "rxmsg_OBJ_MDL_INV_UPD_RSP": 218,
        "rxmsg_OBJ_MDL_POLL_RSP": 34561,
        "rxmsg_OBJ_MDL_GRID_STATUS_RSP": 3,
        "rxmsg_OBJ_MDL_EVENTS_MSG": 1241,
        "rxmsg_OBJ_MDL_SOC_CONFIG_RSP": 3,
        "txmsg_OBJ_MDL_META_REQ": 3,
        "txmsg_OBJ_MDL_ENC_RT_POLL_REQ": 1,
        "txmsg_OBJ_MDL_BMU_POLL_REQ": 1555,
        "txmsg_OBJ_MDL_PCU_POLL_REQ": 1557,
        "txmsg_OBJ_MDL_SECONDARY_CTRL_REQ": 57851,
        "txmsg_OBJ_MDL_GRID_STATUS_REQ": 3,
        "txmsg_OBJ_MDL_EVENTS_ACK": 1241,
        "txmsg_OBJ_MDL_SOC_CONFIG_REQ": 3,
        "txmsg_OBJ_MDL_TNS_START": 9,
        "rxmsg_OBJ_MDL_TNS_START_RSP": 11,
        "txmsg_OBJ_MDL_TNS_END": 10,
        "rxmsg_OBJ_MDL_TNS_END_RSP": 10,
        "txmsg_lvs_poll": 203,
        "zmq_ecaHello": 1,
        "zmq_ecaDevInfo": 37,
        "zmq_ecaNetworkStatus": 25697,
        "zmq_ecaAppMsg": 36050,
        "zmq_streamdata": 124712,
        "zmq_live_debug": 542,
        "zmq_eca_live_debug_req": 42,
        "zmq_nameplate": 397,
        "zmq_ecaSecCtrlMsg": 57851,
        "zmq_meterlog_ok": 1,
        "dmdl_FILES_INDEXED": 3,
        "devPollMissing": 3603,
        "gridProfileTransaction": 19,
        "fsm_retry_timeout": 1,
        "profile_txn_ack": 10,
        "backupSocLimitSet": 58058,
        "backupSocLimitChanged": 2,
        "api_ecagtGetGenRelayState": 124712
    },
    "secctrl": {
        "shutdown": false,
        "freq_bias_hz": 0.19460000097751618,
        "voltage_bias_v": 2.365999937057495,
        "freq_bias_hz_q8": 313,
        "voltage_bias_v_q5": 75,
        "freq_bias_hz_phaseb": 0.0,
        "voltage_bias_v_phaseb": 0.0,
        "freq_bias_hz_q8_phaseb": 0,
        "voltage_bias_v_q5_phaseb": 0,
        "freq_bias_hz_phasec": 0.0,
        "voltage_bias_v_phasec": 0.0,
        "freq_bias_hz_q8_phasec": 0,
        "voltage_bias_v_q5_phasec": 0,
        "configured_backup_soc": 0,
        "adjusted_backup_soc": 0,
        "agg_soc": 89,
        "Max_energy": 10500,
        "ENC_agg_soc": 89,
        "ENC_agg_soh": 100,
        "ENC_agg_backup_energy": 0,
        "ENC_agg_avail_energy": 9345,
        "Enc_commissioned_capacity": 10500,
        "Enc_max_available_capacity": 10500,
        "ACB_agg_soc": 0,
        "ACB_agg_energy": 0
    },
    "relay": {
        "mains_admin_state": "closed",
        "mains_oper_state": "closed",
        "der1_state": 0,
        "der2_state": 0,
        "Enchg_grid_mode": "grid-tied",
        "Solar_grid_mode": "unknown"
    },
    "profile": {
        "message": "Obsolete API, please use ivp/arf/profile"
    },
    "fakeit": {
        "fake_inventory_mode": false
    }
}
vincentwolsink commented 2 months ago

In 0.3.7-beta2 I extended the battery support with more data. There is an endpoint for current power in W. Unfortunately still no endpoint for Wh.

keesvanbemmel commented 2 months ago

Looks good! Do you know if the envoy reports the total battery charge state? The batteries themselves have the SOC, but the envoy doesn't show this in your integration atm for all batteries.

I'm looking for the 94% that is at the top of the screenshot. The other percentages are reported by the integration. Screenshot_20240417-205908

vincentwolsink commented 2 months ago

It should actually. Did you install beta2? Can you make a screenshot of the available sensors on the Envoy?

keesvanbemmel commented 2 months ago

Sorry, didn't check there. It is available indeed!

vincentwolsink commented 2 months ago

@keesvanbemmel Do you have dedicated CTs installed for your battery? In that case it is actually possible to get the kwh readings.

keesvanbemmel commented 2 months ago

I have now. Added a Shelly pro em 50 to this setup that reads the kwh

vincentwolsink commented 2 months ago

I was aiming at Envoy CTs. But this also works ofc. 🙂

keesvanbemmel commented 2 months ago

Is there a way to hook up more than 6 cts to the envoy?

vincentwolsink commented 2 months ago

No, it seems not. Envoy does support CTs specifically for the battery. But in a 3 phase system there is no room for extra CTs. 🤷‍♂️

keesvanbemmel commented 2 months ago

Well this setup with your additions work like a charm. You could close this issue if you want!