iobroker-community-adapters / ioBroker.shelly

Integrate your Shelly devices into ioBroker via MQTT or CoIoT
Other
168 stars 68 forks source link
coap home-automation iobroker iot shelly smarthome

Logo

ioBroker.shelly

NPM version Downloads node-lts Libraries.io dependency status for latest release

GitHub GitHub repo size GitHub commit activity GitHub last commit GitHub issues GitHub Workflow Status

Versions

Beta Stable Installed

The adapter communicates with Shelly devices by REST API and the CoAP or MQTT protocol.

It uses the default Shelly firmware (no flashing of firmware needed!). You will find more and detailed information about the device here: Shelly

Documentation

πŸ‡ΊπŸ‡Έ Documentation

πŸ‡©πŸ‡ͺ Dokumentation

Supported devices

Generation 1 (Gen 1)

Shelly Device CoAP MQTT
Shelly 1 (SHSW-1) >= v3.3.0 >= v3.3.0
Shelly 1 PM (SHSW-PM) >= v3.3.0 >= v3.3.0
Shelly 1L (SHSW-L) >= v4.0.5 >= v4.0.5
Shelly 2 (SHSW-21/SHSW-22) >= v3.3.0 >= v3.3.0
Shelly 2.5 (SHSW-25) >= v3.3.0 >= v3.3.0
Shelly 4 Pro (SHSW-44) >= v3.3.5 >= v3.3.5
Shelly Dimmer (SHDM-1) >= v3.3.0 >= v3.3.0
Shelly Dimmer 2 (SHDM-2) >= v3.3.4 >= v3.3.4
Shelly RGBW (SHRGBWW-01) < v3.4.0 < v3.4.0
Shelly RGBW 2 (SHRGBW2) >= v3.3.0 >= v3.3.0
Shelly i3 (SHIX3-1) >= v3.3.0 >= v3.3.0
Shelly EM (SHEM) >= v3.3.0 >= v3.3.0
Shelly 3EM (SHEM-3) >= v3.3.0 >= v3.3.0
Shelly H&T (SHHT-1) >= v3.3.0 >= v3.3.0
Shelly Smoke (SHSM-01) >= v3.3.0 >= v3.3.0
Shelly Flood (SHWT-1) >= v3.3.0 >= v3.3.0
Shelly Gas (SHGS-1) >= v3.3.3 >= v3.3.3
Shelly Door/Window Sensor (SHDW-1) >= v3.3.0 >= v3.3.0
Shelly Door/Window Sensor 2 (SHDW-2) >= v3.3.5 >= v3.3.5
Shelly2LED (SH2LED) >= v3.3.0 >= v3.3.0
Shelly Plug (SHPLG-1) >= v3.3.0 >= v3.3.0
Shelly Plug S (SHPLG-S) >= v3.3.0 >= v3.3.0
Shelly Plug 2 (SHPLG-2) >= v3.3.0 >= v3.3.0
Shelly Sense (SHSEN-1) >= v3.3.0 >= v3.3.0
Shelly Bulb (SHBLB) >= v3.3.0 >= v3.3.0
Shelly Bulb Duo (SHBDUO-1) >= v3.3.0 >= v3.3.0
Shelly Color Bulb (SHCB-1) >= v4.0.5 >= v4.0.5
Shelly Vintage (SHVIN-1) >= v3.3.0 >= v3.3.0
Shelly Uni (SHUNI-1) >= v4.0.4 >= v4.0.4
Shelly Button (SHBTN-1) >= v3.3.3 >= v3.3.3
Shelly Button (SHBTN-2) >= v4.0.5 >= v4.0.5
Shelly Motion (SHMOS-01) >= v4.0.6 >= v4.0.6
Shelly TRV (SHTRV-01) >= v6.0.0 >= v6.0.0
Shelly Motion 2 (SHMOS-02) => v6.2.0 >= v6.2.0

Generation 2 (Gen 2)

Shelly Device CoAP MQTT
Shelly Plus 1 (shellyplus1) ❌ >= v5.0.0
Shelly Plus 1 PM (shellyplus1pm) ❌ >= v5.0.0
Shelly Plus 2 PM (shellyplus2pm) ❌ >= v5.2.0
Shelly Plus i4 (shellyplusi4) ❌ >= v5.3.0
Shelly Plus i4 DC (shellyplusi4) ❌ >= v5.3.0
Shelly Plus 0-10V (shellyplus010v) ❌ >= v6.9.0
Shelly Pro 1 (shellypro1) ❌ >= v5.2.0
Shelly Pro 1 PM (shellypro1pm) ❌ >= v5.2.0
Shelly Pro 2 (shellypro2) ❌ >= v5.2.0
Shelly Pro 2 PM (shellypro2pm) ❌ >= v5.2.0
Shelly Pro 3 (shellypro3) ❌ >= v6.2.0
Shelly Pro 4 PM (shellypro4pm) ❌ >= v5.0.0
Shelly Pro 3 EM (shellypro3em) ❌ >= v6.4.0
Shelly Pro Dimmer 1 PM (shellyprodm1pm) ❌ >= v8.0.0
Shelly Pro Dimmer 2 PM (shellyprodm2pm) ❌ >= v7.0.0
Shelly Pro EM 2x50A ❌ >= v8.1.0
Shelly Plus H&T (shellyplusht) ❌ >= v6.2.0
Shelly Plus Smoke (shellyplussmoke) ❌ >= v6.5.0
Shelly Bluetooth Gateway (shellyblugw) ❌ >= v6.5.0
Shelly Plus Plug S (shellyplusplugs) ❌ >= v6.4.0
Shelly Plus PM Mini (shellypmmini) ❌ >= v6.4.5
Shelly Plus 1 Mini (shellyplus1mini) ❌ >= v6.4.5
Shelly Plus 1 PM Mini (shellyplus1pmmini) ❌ >= v6.4.5
Shelly Plus Uni (shellyplusuni) ❌ >= v8.0.0
Shelly Wall Display (shellywalldisplay) ❌ >= v7.0.0
Shelly Plus RGBW PM (shellyplusrgbwpm) ❌ >= v8.2.0

Generation 3 (Gen 3)

Shelly Device CoAP MQTT
Shelly 1 Mini Gen3 (shelly1minig3) ❌ >= v7.0.0
Shelly 1 PM Mini Gen3 (shelly1pmminig3) ❌ >= v7.0.0
Shelly PM Mini Gen3 (shellypmminig3) ❌ >= v7.0.0
Shelly H&T Gen3 (shellyhtg3) ❌ >= v8.0.0
Shelly 1 PM Gen3 (shelly1pmg3) ❌ >= v8.0.0
Shelly 1 Gen3 (shelly1g3) ❌ >= v8.0.0
Shelly 2 PM Gen3 (shelly2pmg3) ❌ >= v8.3.0
Shelly 0/1-10V PM Gen3 (shelly0110dimg3) ❌ >= v8.4.0
Shelly Plug S Gen3 (shellyplugsg3) ❌ >= v8.5.0
Shelly BLU Gateway Gen3 (shellyblugwg3) ❌ >= v8.5.0
Shelly I4 / I4DC Gen3 (shellyi4g3) ❌ >= v8.5.0

Bluetooth Low Energy (BLU)

Experimental - see documentation for details (Shelly Scripting required)

Adapter version >= v6.8.0 required for:

Adapter version >= v8.2.0 required for:

NOT Supported devices

Sentry

This adapter uses Sentry libraries to automatically report exceptions and code errors to the developers. For more details and for information how to disable the error reporting see Sentry-Plugin Documentation! Sentry reporting is used starting with js-controller 3.0.

Changelog

8.5.0 (2024-11-24)

8.4.0 (2024-10-20)

8.3.0 (2024-10-10)

8.2.1 (2024-09-23)

8.2.0 (2024-09-19)

License

The MIT License (MIT)

Copyright (c) 2018-2024 Thorsten Stueben thorsten@stueben.de, Apollon77 iobroker@fischer-ka.de and Matthias Kleine info@haus-automatisierung.com

Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions:

The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.

THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.