Current behavior / steps to reproduce:
- recall a calibration setting 1, display shows C1
- send a serial command to change the frequency range
Result: display still shows C1
Expected result: di…
-
![screenshot](https://user-images.githubusercontent.com/46676744/67643701-d8063300-f922-11e9-8d20-a603cd2859bf.png)
![screenshot-tdr](https://user-images.githubusercontent.com/46676744/67647070-8f0…
qrp73 updated
5 years ago
-
STR:
1) open console
2) send marker 1 1000
3) make sure device hung
qrp73 updated
5 years ago
-
After flashing ALL_FF to clear memory and then flashing NanoVNA-H__900_aa_20191003.dfu the device will boot every time with no issue.
I then calibrate touchscreen - not issues while device stays o…
-
This is related with this issue: https://github.com/ttrftech/NanoVNA/issues/70
The bug didn't fixed. The spikes are reduced but don't disappears.
Try rollback your changes and apply my small fix…
qrp73 updated
5 years ago
-
I have been drilling down on a persistent glitch measuring an inductor with relatively high impedance.
If I understand the system properly, I have obtained raw output by turning off "correction" in…
-
Have here "strange" Peaks after upgrading to v0.2.1. v0.2.2 shows same behaviour. Took Screenshots with nanoVNA-saver to show the Problem. The v0.2.0 from 27. Sept. seems ok.
Screenshot from 0.2.0 …
-
Hi hugen,
I'm an original developer of NanoVNA.
When I knew that you made the clone of my project, I very surprised that you made PCB from schematics, and as an enthusiast, I felt pleased with yo…
-
I suspect the accuracy of S_11 and S_21 are fairly predictable, based on the specs published on the NanoVNA. You could find the approximate delta of the calculated values for the markers using total …
-
There is exists trace format DELAY in the menu, but it doesn't works, because it is not implemented in the code.
I implemented group delay (GD) in this changeset: https://github.com/ttrftech/NanoVN…
qrp73 updated
5 years ago