wasilukm / hoymiles-mqtt

Send data from Hoymiles PV plant to Home Assistant without cloud
MIT License
47 stars 9 forks source link
home-assistant modbus-tcp mqtt python

Hoymiles MQTT

pypi python Build Status codecov

Send data from Hoymiles photovoltaic installation to Home Assistant through MQTT broker.

The tool periodically communicates with Hoymiles DTU (Pro) through ModbusTCP and sends gathered data to MQTT broker. Data to MQTT broker are sent with topics that can be recognized by Home Assistant. In a result DTU and each micro-inverter can be represented in Home Assistant as separate device with a set of entities. Example:

MQTT Devices

MQTT Entities

DTU device represents overall data for the installation:

Each micro-inverter has the following entities:

Depending on the installation (number of micro-inverter), the tool may create many entities. One may limit the entities or with the option --mi-entities.

A micro-inverter can support multiple ports (PV panels), their states are represented by:

Publishing of these entities can be controlled with --port-entities.

The following entities are sent only when the inverter's operating status is greater than 0: grid_voltage, grid_frequency, temperature, pv_voltage, pv_current, pv_power.

Additionally, today_production and total_production are updated only when the inverter's operating status is greater than 0 and the new value is greater than the previous one. This is to prevent drops in measurements which shall be only increasing.

Usage

Prerequisites

From command line

usage: python3 -m hoymiles_mqtt [-h] [-c CONFIG] --mqtt-broker MQTT_BROKER [--mqtt-port MQTT_PORT]
                                [--mqtt-user MQTT_USER] [--mqtt-password MQTT_PASSWORD] [--mqtt-tls]
                                [--mqtt-tls-insecure] --dtu-host DTU_HOST [--dtu-port DTU_PORT]
                                [--modbus-unit-id MODBUS_UNIT_ID] [--query-period QUERY_PERIOD]
                                [--microinverter-type {MI,HM}]
                                [--mi-entities MI_ENTITIES [MI_ENTITIES ...]]
                                [--port-entities PORT_ENTITIES [PORT_ENTITIES ...]]
                                [--expire-after EXPIRE_AFTER] [--comm-timeout COMM_TIMEOUT]
                                [--comm-retries COMM_RETRIES]
                                [--comm-retry-on-empty COMM_RETRY_ON_EMPTY]
                                [--comm-close-comm-on-error COMM_CLOSE_COMM_ON_ERROR]
                                [--comm-strict COMM_STRICT]
                                [--comm-reconnect-delay COMM_RECONNECT_DELAY]
                                [--log-level {DEBUG,INFO,WARNING,ERROR,CRITICAL}] [--log-file LOG_FILE]
                                [--log-to-console]

options:
  -h, --help            show this help message and exit
  -c CONFIG, --config CONFIG
                        Config file path (default: None)
  --mqtt-broker MQTT_BROKER
                        Address of MQTT broker [env var: MQTT_BROKER] (default: None)
  --mqtt-port MQTT_PORT
                        MQTT broker port. Note that when using TLS connection you may need to specify
                        port 8883 [env var: MQTT_PORT] (default: 1883)
  --mqtt-user MQTT_USER
                        User name for MQTT broker [env var: MQTT_USER] (default: None)
  --mqtt-password MQTT_PASSWORD
                        Password to MQTT broker [env var: MQTT_PASSWORD] (default: None)
  --mqtt-tls            MQTT TLS connection [env var: MQTT_TLS] (default: False)
  --mqtt-tls-insecure   MQTT TLS insecure connection (only relevant when using with the --mqtt-tls
                        option). Do not use in production environments. [env var: MQTT_TLS_INSECURE]
                        (default: False)
  --dtu-host DTU_HOST   Address of Hoymiles DTU [env var: DTU_HOST] (default: None)
  --dtu-port DTU_PORT   DTU modbus port [env var: DTU_PORT] (default: 502)
  --modbus-unit-id MODBUS_UNIT_ID
                        Modbus Unit ID [env var: MODBUS_UNIT_ID] (default: 1)
  --query-period QUERY_PERIOD
                        How often (in seconds) DTU shall be queried. [env var: QUERY_PERIOD] (default:
                        60)
  --microinverter-type {MI,HM}
                        Type od microinverters in the installation. Mixed types are not supported. [env
                        var: MICROINVERTER_TYPE] (default: MI)
  --mi-entities MI_ENTITIES [MI_ENTITIES ...]
                        Microinverter entities that will be sent to MQTT. By default all entities are
                        presented. [env var: MI_ENTITIES] (default: ['grid_voltage', 'grid_frequency',
                        'temperature', 'operating_status', 'alarm_code', 'alarm_count', 'link_status'])
  --port-entities PORT_ENTITIES [PORT_ENTITIES ...]
                        Microinverters' port entities (in fact PV panel entities) that will be sent to
                        MQTT. By default all entities are presented. [env var: PORT_ENTITIES] (default:
                        ['pv_voltage', 'pv_current', 'pv_power', 'today_production',
                        'total_production'])
  --expire-after EXPIRE_AFTER
                        Defines number of seconds after which DTU or microinverter entities expire, if
                        updates are not received (for example due to communication issues). After
                        expiry, entities become unavailable in Home Assistant.By default it is 0, which
                        means that entities never expire. When different than 0, the value shallbe
                        greater than the query period. This setting does not apply to entities that
                        represent a total amount such as daily energy production (they never expire).
                        [env var: EXPIRE_AFTER] (default: 0)
  --comm-timeout COMM_TIMEOUT
                        Additional low level modbus communication parameter - request timeout. [env var:
                        COMM_TIMEOUT] (default: 3)
  --comm-retries COMM_RETRIES
                        Additional low level modbus communication parameter - max number of retries per
                        request. [env var: COMM_RETRIES] (default: 3)
  --comm-retry-on-empty COMM_RETRY_ON_EMPTY
                        Additional low level modbus communication parameter - retry if received an empty
                        response. [env var: COMM_RETRY_ON_EMPTY] (default: False)
  --comm-close-comm-on-error COMM_CLOSE_COMM_ON_ERROR
                        Additional low level modbus communication parameter - close connection on error.
                        [env var: COMM_CLOSE_COMM_ON_ERROR] (default: False)
  --comm-strict COMM_STRICT
                        Additional low level modbus communication parameter - strict timing, 1.5
                        character between requests. [env var: COMM_STRICT] (default: True)
  --comm-reconnect-delay COMM_RECONNECT_DELAY
                        Additional low level modbus communication parameter - delay in milliseconds
                        before reconnecting. [env var: COMM_RECONNECT_DELAY] (default: 300000)
  --log-level {DEBUG,INFO,WARNING,ERROR,CRITICAL}
                        Python logger log level. Default: WARNING [env var: LOG_LEVEL] (default:
                        WARNING)
  --log-file LOG_FILE   Python logger log file. Default: not writing into a file [env var: LOG_FILE]
                        (default: None)
  --log-to-console      Enable logging to console. [env var: LOG_TO_CONSOLE] (default: False)

Args that start with '--' can also be set in a config file (specified via -c). Config file syntax
allows: key=value, flag=true, stuff=[a,b,c] (for details, see syntax at https://goo.gl/R74nmi). In
general, command-line values override environment variables which override config file values which
override defaults.

Docker

Build an image

docker build https://github.com/wasilukm/hoymiles-mqtt.git#v0.8.1 -t hoymiles_mqtt

Run (change IP addresses)

docker run -d -e MQTT_BROKER=192.168.1.101 -e DTU_HOST=192.168.1.100 hoymiles_mqtt

Please note, depending on the needs more options can be specified with -e. See above for all possible options. For example to enable logging to console with DEBUG logging level:

docker run -d -e MQTT_BROKER=192.168.1.101 -e DTU_HOST=192.168.1.100 -e LOG_LEVEL=DEBUG -e LOG_TO_CONSOLE=true hoymiles_mqtt

NOTE: DEBUG level is very verbose, so should be used only for troubleshooting.

Troubleshooting

Credits

This package was created with Cookiecutter and the waynerv/cookiecutter-pypackage project template.