WA9266_fix_failing_crc_check
#154
thomas-hutterer-tik
opened
5 months ago
1
Failed to read response! CRC Error in received frame
#153
thomas-hutterer-tik
opened
5 months ago
1
ModbusSerialTransport.getInterFrameDelay returns wrong values if the baudrate is below 19200
#152
pierantoniomerlino
opened
8 months ago
0
feat: Add support for providing an optional java.net proxy for.
#151
VrolijkxCentrica
closed
6 months ago
0
Android Devices
#150
ThingCoder
closed
7 months ago
1
`jSerialComm 2.9.3` dependency blocks `jSerialComm` upgrade
#149
farzadpanahi
closed
8 months ago
1
Modbus Serial Event Disconnected
#148
caiokrauel
closed
8 months ago
1
ModbusMasterFactory should be in test dir?
#147
raisercostin
closed
8 months ago
1
SerialConnection.writeBytes(SerialConnection.java:199) method did not exist
#146
sheng930920
closed
7 months ago
1
fix: add SerialPort LISTENING_EVENT_PORT_DISCONNECTED listener - to prevent hanging OS port ref
#145
MartynasRim
closed
11 months ago
0
Serial port is left hanging in OS if it gets physically disconnected
#144
MartynasRim
closed
11 months ago
1
Proposed changes to stopbits method descriptions
#143
pan-henryk
closed
1 year ago
0
Misleading documentation for SerialParameters
#142
pan-henryk
closed
1 year ago
2
Add user input validation on SerialParameters.java.
#141
AmbroiseS
closed
1 year ago
0
Add checkstyle to project
#140
AmbroiseS
closed
1 year ago
1
Update jserialcom to 2.10.3
#139
AmbroiseS
closed
1 year ago
3
Bump jSerialComm for fixed POSIX signal handling
#138
sirhcel
closed
1 year ago
0
ModbusTCPMaster: Fix incorrect reconnect parameter documentation
#137
bantu
closed
1 year ago
0
Request for quick example update for logging
#136
dannaughton
closed
1 year ago
2
Add capability to bind the Socket to specific local interface.
#135
tamiradler
closed
11 months ago
2
My RS485 can only send, but not receive.
#134
Conmi-WhiteJoker
closed
1 year ago
1
Misleading documentation for reconnect parameter in ModbusTCPMaster
#133
bantu
closed
1 year ago
1
Unexpected Connection Closed by peer
#132
chaos84731
closed
1 year ago
2
Ctrl+C SIGINT does not shutdown JVM with open SerialConnection
#131
hauges
closed
1 year ago
1
Registry edit popup
#130
ghost
closed
1 year ago
1
Production use; Repository maintenance
#129
vinerich
closed
1 year ago
1
modbus slave factory getSlave fix
#128
mkurt
closed
1 year ago
0
Added equals & hashcode method to ModbusTCPMaster & TCPMasterConnection
#127
aDramaQueen
closed
1 year ago
0
Move parts of DEBUG logging to TRACE
#126
gitMiguel
closed
1 year ago
3
Cannot open specific virtual COM port configured 8N2 on Windows, which works on legacy javax.comm driver
#125
pan-henryk
closed
1 year ago
3
Bump log4j-core from 2.14.1 to 2.17.1
#124
dependabot[bot]
closed
2 years ago
1
ModbusTCPMaster: equals & hashCode method
#123
aDramaQueen
closed
2 years ago
2
Bump log4j-core from 2.14.1 to 2.17.0
#122
dependabot[bot]
closed
2 years ago
1
Bump log4j-core from 2.14.1 to 2.16.0
#121
dependabot[bot]
closed
2 years ago
1
Bump log4j-core from 2.14.1 to 2.15.0
#120
dependabot[bot]
closed
2 years ago
1
How to get response when I write a command using SerialConnection writeBytes() method
#119
aviral1999099
closed
3 years ago
3
Add remaining RS-485 configuration parameters for Linux
#118
sirhcel
closed
2 years ago
6
Add support for explicitly configuring RS-485 mode
#117
sirhcel
closed
3 years ago
2
read write mismatch
#116
aniluoh
closed
3 years ago
1
switched to scheduled executor service instead of timer
#115
mkurt
closed
3 years ago
1
Calling the readInputDiscretes() method multiple times under certain conditions on the same ModbusTCPMaster instance resulted in an error.
#114
kazuyatada
closed
3 years ago
1
How to add special function in ModbusMaster
#113
Julien-Faure
closed
3 years ago
4
Problem with raspbian RS-485 communication
#112
pan-henryk
closed
3 years ago
7
Bump junit from 4.12 to 4.13.1
#111
dependabot[bot]
closed
3 years ago
1
Noob Java Modbus RTU Master Progoramm
#110
Mabignix
closed
4 years ago
0
Unable to read status (register) from the device
#109
parthibunn
closed
4 years ago
2
TCP Connection idle timeout
#108
akochubey2004
closed
4 years ago
4
Bump log4j-core from 2.3 to 2.13.2
#107
dependabot[bot]
closed
4 years ago
1
Holding register function not working as per expectation in rtu mode of modbus slave
#106
DhruvilDhanani
closed
4 years ago
2
Updated jSerialComm version from 2.5.3 to 2.6.1, java.lang.NoSuchMethodError Exception happen
#105
liucunjie
closed
4 years ago
0